How to run the STEVAL-IOD004V1 smart industrial sensor
To run the STEVAL-IOD004V1 main board with the
preloaded firmware, follow the procedure
below.
Step 1.
Connect the board to an IO-Link master embedding a standard M8 4-way socket side connector.
If the IO-Link master and the available cabling are M12, you can use the M8 to M12 connector adapter
provided in the
Once the STEVAL-IOD004V1 is connected to a master, it should recognize the sensor node thanks to
the IODD file preloaded in the
, assuming that the cable is correctly powering the smart
industrial sensor node at 24 V and below 32 V.
Step 2.
Use the
compact in-circuit debugger and programmer for STM32 included in the kit to
debug code for firmware analysis or for code modification.