Operating Manual
Shuttle
™
ULT
:
25
-86
º
C
Portable Ultra Low Temperature Freezer
P.O. Box 428 Athens, Ohio 45701, USA
t:
740.592.2655
f:
740.592.2695
www.stirlingshuttle.com
Страница 1: ...Operating Manual Shuttle ULT 25 86 C Portable Ultra Low Temperature Freezer P O Box 428 Athens Ohio 45701 USA t 740 592 2655 f 740 592 2695 www stirlingshuttle com...
Страница 2: ......
Страница 3: ...er Temperature Alarm 10 How to silence the audible temperature alarm 10 To postpone an alarm 10 Error Conditions 11 Locking the Panel 11 To lock the freezer panel 11 To unlock the freezer panel 11 How...
Страница 4: ...ts in rain or other severe weather Do not use solvents to clean the panel or the outside or inside of the freezer An ultra low temperature freezer is qualitatively different than a home freezer At 80...
Страница 5: ...g the opposite end into the ULT 25 6 Notes on operation in a vehicle A The ULT 25 will operate on battery power for a limited time before the battery is drained and the vehicle cannot be started This...
Страница 6: ...n more detail on page 7 3 Locking latch Can be locked to provide sample security 4 Access port For thermocouple wires purge gas etc 5 Cleanable filter Helps protect the heat rejection fins from dust 6...
Страница 7: ...ton and Set T LED This must be pressed to adjust the Set Temperature D buttons Used to adjust Set Point Temperature when the display shows S E Error LED Indicates when there is an electrical mechanica...
Страница 8: ...IONS Change to Preset Press and hold Set until Set T LED glows S displayed then Preset 1 2 or 3 Postpone Over T Alarm When Over T light glows press Preset 3 until time shows 1 0 h If Over T LED is not...
Страница 9: ...he current set temperature Press the Set T button briefly The current set temperature will be displayed with the letter S After eight seconds of inactivity the display will revert to the current tempe...
Страница 10: ...shown in the seven segment display If this is the desired Set Temperature the user can either Briefly press the Set T button to turn off the Set T LED OR Wait for approximately eight seconds when the...
Страница 11: ...ee times The Locked indicator LED will then turn off The freezer will still indicate over temperature alarms or error conditions while it is locked The user has to unlock the panel to handle those ala...
Страница 12: ...completely removed Gently clean the filter with a vacuum cleaner If there are stubborn residues use a soft brush to work them loose Storage 1 Turn off the power and allow the freezer to come to room...
Страница 13: ...Clean air filter screen Remove air flow obstructions Inadequate power Assure that the wall plug is firmly seated Remove any dirt or burnt material inside the automotive accessory socket or on the plug...
Страница 14: ...n to 86 C from Ambient Air Temp Empty Middle Height Steady State Non Cycling TEMPERATURE C TIME HOUR 40 20 0 20 40 60 80 100 0 9 12 3 6 15 18 21 24 PULL DOWN AND WARM UP CHARACTERISTICS 25 C AMBIENT 1...
Страница 15: ...representation as to this WARRANTY except duly authorized officers of Global Cooling Inc 7 Global Cooling Inc agrees if instructions as to operation and use are strictly followed and power sources cir...
Страница 16: ...2 11 2011 Stirling Ultracold Global Cooling Inc All Rights Reserved HUMM technology is manufactured under U S and International patents Stirling Ultracold Shuttle and HUMM are trademarks of Global Coo...