background image

State: 04.12.2020 p. 5

Mounting instructions for multiplay „ascendo 2 robinia“

Item-No. 51 7510 601

©  stilum GmbH, Gewerbegebiet Larsheck, D-56271 Kleinmaischeid  •  Tel. +49 (0) 2689 92790-0  •  All rights and product modifications reserved.

Diagram 5c: connection climbing slant

F

H

F (1 : 10)

H (1 : 10)

I

I (1 : 10)

J

J (1 : 20)

OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE 

TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER 

ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER- 

WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

3

 

ascendo 1B

Benennung

Gepr.

Blatt

Datum

Projekt

Gez.

Zeichnungsnummer

1:100

A3

Name

Explosion

1026-00-00

Maßstab

Simonis

xx.xx.xx

 

 

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

Diagram 5d: connection wobble bridge

Diagram 5a: connection 

firemans pole

Diagram 5b: connection slide

B

C

D

E

OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE 

TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER 

ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER- 

WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

2

 

ascendo 1A

Benennung

Gepr.

Blatt

Datum

Projekt

Gez.

Zeichnungsnummer

1:100

A3

Name

Übersicht

1026-00-00

Maßstab

Simonis

xx.xx.xx

 

 

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

B

C

D

E

OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE 

TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER 

ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER- 

WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

2

 

ascendo 1A

Benennung

Gepr.

Blatt

Datum

Projekt

Gez.

Zeichnungsnummer

1:100

A3

Name

Übersicht

1026-00-00

Maßstab

Simonis

xx.xx.xx

 

 

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

F

H

F (1 : 10)

H (1 : 10)

I

I (1 : 10)

J

J (1 : 20)

OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE 

TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER 

ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER- 

WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

3

 

ascendo 1B

Benennung

Gepr.

Blatt

Datum

Projekt

Gez.

Zeichnungsnummer

1:100

A3

Name

Explosion

1026-00-00

Maßstab

Simonis

xx.xx.xx

 

 

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

F

H

F (1 : 10)

H (1 : 10)

I

I (1 : 10)

J

J (1 : 20)

OHNE SCHRIFTLICHE ZUSTIMMUNG DER KAISER GMBH DARF DIESE 

TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT, NOCH DRITTEN MITGETEILT ODER 

ZUGÄNGLICH GEMACHT WERDEN, NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER- 

WENDET WERDEN. ZUWIDERHANDLUNGEN WERDEN URHEBERRECHTLICH VERFOLGT.

3

 

ascendo 1B

Benennung

Gepr.

Blatt

Datum

Projekt

Gez.

Zeichnungsnummer

1:100

A3

Name

Explosion

1026-00-00

Maßstab

Simonis

xx.xx.xx

 

 

Gewerbegebiet Larsheck

56271 Kleinmaischeid

Deutschland

Diagram 5e: connection 

climbing arc

Содержание ascendo 2 robinia

Страница 1: ...51 7510 601 stilum GmbH Gewerbegebiet Larsheck D 56271 Kleinmaischeid Tel 49 0 2689 92790 0 All rights and product modifications reserved climbing arc tower wobble bridge slide climbing slant fireman s pole climbing wall rail post post shoe Diagram 1 Overall view of the play equipment ...

Страница 2: ...ing period of 10 14 days depending on weather conditions and foundation size fill up and compress the holes between the foundation and the foundation hole with excavation 6 Clean the surface of the foundations and start with the installation of the play equipment Diagram 2 Top view Reinforcement plan Concrete foundation with reinforcement Foundation BSt 500S Stirrups Ø 8 mm lengthwise and cross Co...

Страница 3: ... Larsheck 56271 Kleinmaischeid Deutschland Beton concrete gewachsenes Erdreich natural ground Legende stoßdämpfender Boden shock absorbing floor ES 09 09 20 stoßdämpfender Boden A Datum Änderung Rev 5392 450 400 1716 2921 A A 3656 1511 3650 4813 4031 1750 600 600 950 275 2871 1846 2904 1750 400 1100 500 1000 500 979 950 1750 561 2029 1996 711 A A 5410 6336 OHNE SCHRIFTLICHE ZUSTIMMUNG DER CONRADI ...

Страница 4: ...enennung Gepr Blatt Datum Projekt Gez Zeichnungsnummer 1 20 A3 Name Feuerwehrstange mit Bogen 1025 11 00 Maßstab Simonis xx xx xx Gewerbegebiet Larsheck 56271 Kleinmaischeid Deutschland OHNE SCHRIFTLICHE ZUSTIMMUNG DER CONRADI KAISER GMBH DARF DIESE TECHNISCHE UNTERLAGE WEDER VERVIELFÄLTIGT NOCH DRITTEN MITGETEILT ODER ZUGÄNGLICH GEMACHT WERDEN NOCH IN SONSTIGER WEISE MISSBRÄEUCHLICH VER WENDET WE...

Страница 5: ... 49 0 2689 92790 0 All rights and product modifications reserved Diagram 5c connection climbing slant J Diagram 5d connection wobble bridge Diagram 5a connection firemans pole Diagram 5b connection slide C C F H I J H I ascendo 1B Benennung Gepr Datum Projekt Gez Zeichnungsnummer Name Explosion 1026 00 00 Simonis xx xx xx Diagram 5e connection climbing arc ...

Страница 6: ...es STAINLESS STEEL NOTE Play equipment which contain components made of stainless steel should not come with normal steel parts in contact Those steel parts may rub off and leave small steel particles in combination with moisture brown rust stains MAINTENANCE If such corrosion occur on stainless steel parts they are fine to remove with an abrasive 240 grit Please take care when transporting and se...

Страница 7: ...opropyl alcohol or acetone However it should be noted that the dissolved soiling is not spread over the sur face again Do not use any chlorid or hydrochloric containing cleaning products nor scouring powder bleaching or silver polish cleaner Cleaning intervals depend on type and degree of soiling as well as on demands made on optical characteristics Therefore cleaning is advisable at intervals of ...

Отзывы: