Maintenance
5
Preserving operational readiness
Preserving operational readiness
7097_003-003
1
De-icing the evaporator
NOTE
Gas cools significantly upon evaporation. If
the evaporator is not warmed sufficiently by
the coolant circulation in the engine, it may ice
over. The gas supply can be interrupted if the
evaporator ices over. This causes the engine
to come to a halt.
– Open the bonnet; see
= "Motorhaube_oeffnen" not found!
– Check to see whether the evaporator has
iced over.
If the evaporator has iced over:
– Disconnect the connection assembly (1).
The gas shut-off valve is closed. The gas flow
to the evaporator is blocked.
– Try to start the engine again.
If the engine starts, leave it running until it
stalls again due to the lack of gas. This will
discharge any gas still in the evaporator.
CAUTION
Risk of damage to components!
If the engine is prematurely turned off via the key
switch, residue gas may remain in the evaporator.
Undercooled gas left in the evaporator expands
upon heating. This can lead to excessive overpres-
sure in the evaporator and can cause component
damage.
– If the evaporate ices over, do not switch off the
engine using the key switch.
– First of all, allow the engine to stall due to the lack
of gas.
– Make sure that the engine has stopped.
– Once the engine has stopped, switch off the key
switch.
– Switch off the key switch.
57348011850 EN - 02/2019 - 11
335
Содержание RX70-40
Страница 2: ......
Страница 4: ......
Страница 13: ...1 Foreword ...
Страница 33: ...2 Safety ...
Страница 66: ...2 Safety Emissions 54 57348011850 EN 02 2019 11 ...
Страница 67: ...3 Overviews ...
Страница 78: ...3 Overviews Operating devices and display elements 66 57348011850 EN 02 2019 11 ...
Страница 79: ...4 Operation ...
Страница 320: ...4 Operation Decommissioning 308 57348011850 EN 02 2019 11 ...
Страница 321: ...5 Maintenance ...
Страница 328: ...5 Maintenance General maintenance information 316 57348011850 EN 02 2019 11 ...
Страница 332: ...5 Maintenance General maintenance information 320 57348011850 EN 02 2019 11 ...
Страница 334: ...5 Maintenance General maintenance information 322 57348011850 EN 02 2019 11 ...
Страница 364: ...5 Maintenance Preserving operational readiness 352 57348011850 EN 02 2019 11 ...
Страница 371: ...6 Technical data ...
Страница 382: ...6 Technical data Fuse assignment 370 57348011850 EN 02 2019 11 ...
Страница 391: ......
Страница 392: ...STILL GmbH 57348011850 EN 02 2019 11 ...