CAUTION
Potential for damage to the battery male connector!
If the battery male connector is disconnected or con-
nected while the key switch is switched on or while
the battery charger is under load, an arc or a tran-
sition spark will be produced at the battery male
connector. This can lead to erosion at the contacts
and can considerably shorten the service life of the
contacts.
–
Switch off the key switch or the battery charger
before the battery male connector is disconnected
or connected.
–
Do not disconnect the battery male connector
while under load, except in an emergency.
Ventilation gap
The ventilation gaps between the battery cov-
er and the chassis are used for forced-air
cooling of the battery compartment.
–
Do not block the ventilation gaps.
–
If the battery cover is deformed, contact the
authorised service centre.
Charging the lead-acid battery
DANGER
Explosive gases are generated during
charging!
–
Ensure that work areas are adequate-
ly ventilated.
–
To ensure sufficient ventilation, the
battery door must be kept open dur-
ing the charging process.
–
If the industrial truck is equipped with
a fabric structure, open at least one
side of the fabric structure completely.
Operation
4
Handling the lead-acid batteries
205
50078078001 EN - 07/2022 - 04
Содержание LXT 120
Страница 2: ......
Страница 12: ......
Страница 13: ...1 Foreword ...
Страница 37: ...2 Safety ...
Страница 59: ...3 Overviews ...
Страница 62: ...Overviews 3 Display control unit 50 50078078001 EN 07 2022 04 ...
Страница 63: ...4 Operation ...
Страница 117: ...The softkey is also located in the Driving menu Operation 4 Lighting 105 50078078001 EN 07 2022 04 ...
Страница 265: ...5 Maintenance ...
Страница 285: ...6 Technical data ...
Страница 323: ......
Страница 324: ...STILL GmbH 50078078001 EN 07 2022 04 ...