The exact procedure for this insulation testing
is described in the workshop manual for this
truck.
NOTE
The truck's electrical system and drive batter-
ies must be checked separately.
Test values for the drive battery
Component
Recommended
test voltage
Measurements
Nominal volt-
age U
Batt
Test values
Battery
50 VDC
Batt+
Batt-
Battery tray
24 volts
> 1200 Ω
100 VDC
48 volts
> 2400 Ω
100 VDC
80 volts
> 4000 Ω
Test values for the entire truck
Nominal volt-
age
Test voltage
Test values for new trucks
Minimum values over the
duration of the service life
24 volts
50 VDC
Min. 50 kΩ
> 24 kΩ
48 volts
100 VDC
Min. 100 kΩ
> 48 kΩ
80 volts
100 VDC
Min. 200 kΩ
> 80 kΩ
Safety
2
Safety tests
28
50028011505 EN - 03/2022 - 06
Содержание ECV 10
Страница 2: ......
Страница 4: ......
Страница 9: ...1 Introduction ...
Страница 28: ...Introduction 1 Residual risks 20 50028011505 EN 03 2022 06 ...
Страница 29: ...2 Safety ...
Страница 42: ...Safety 2 EMC Electromagnetic compatibility 34 50028011505 EN 03 2022 06 ...
Страница 43: ...3 Views ...
Страница 51: ...4 Operation ...
Страница 76: ...Operation 4 Transporting the truck 68 50028011505 EN 03 2022 06 ...
Страница 77: ...5 Maintenance ...
Страница 85: ...Lubrication point Maintenance 5 Maintenance work 77 50028011505 EN 03 2022 06 ...
Страница 94: ...Maintenance 5 Malfunction analysis 86 50028011505 EN 03 2022 06 ...
Страница 95: ...6 Technical data ...
Страница 96: ...ECV 10 Technical Datasheet Technical data 6 ECV 10 Technical Datasheet 88 50028011505 EN 03 2022 06 ...
Страница 105: ......
Страница 106: ...STILL GmbH 50028011505 EN 03 2022 06 ...