19.2
Product Support and Assis‐
tance on Use
Product support and assistance on use are avail‐
able from STIHL servicing dealers.
For contacts and other information, please visit
https://support.stihl.com or www.stihl.com.
20 Specifications
20.1
STIHL HTA 135 pole pruner
Permitted batteries:
–
STIHL AP
–
STIHL AR
–
Weight without battery: 6.6 kg
–
Max. oil tank capacity: 220 cc (0.22 l)
–
Degree of electrical protection: IPX4 (protec‐
tion against splash water from any direction)
The running time is shown at www.stihl.com/
20.2
Chain Sprockets
The following chain sprockets may be used:
–
7-tooth for 3/8" P
–
8-tooth for 1/4" P
20.3
Minimum Groove Depth of
Guide Bars
The minimum groove depth depends on the pitch
of the guide bar.
–
3/8" P: 5 mm
–
1/4" P: 4 mm
20.4
STIHL AP battery
–
Battery technology: lithium-ion
–
Voltage: 36 V
–
Capacity in Ah: see rating label
–
Energy content in Wh: see rating label
–
Weight in kg: see rating label
–
Permissible temperature range for operation
and storage: + 10 °C to + 50 °C
–
Bluetooth
®
radio interface (only for batteries
with ):
–
Data connection: Bluetooth
®
5.1. The
mobile appliance must be compatible with
Bluetooth
®
Low Energy 5.0 and support
Generic Access Profile (GAP).
–
Frequency band: ISM band 2.4 GHz
–
Maximum RF power transmitted: 1 mW
–
Signal range: approx. 10 m. The signal
strength depends on the ambient conditions
and the mobile terminal. Signal range can
vary greatly depending on local conditions,
including the receiver. The range may be
perceptibly reduced inside enclosed rooms
and through metal barriers (such as walls,
shelves or cases).
–
Mobile appliance operating system require‐
ments: Android or iOS (current version or
higher)
20.5
Sound Values and Vibration
Values
K-value (uncertainty) for sound pressure levels is
2 dB(A). K-value for sound power levels is 2
dB(A). The K-value for vibration levels is 2 m/s².
STIHL recommends wearing ear defenders.
–
Sound pressure level L
pA
measured according
to ISO 22868 for 3/8" P: 88 dB(A)
–
Sound pressure level L
pA
measured according
to ISO 22868 for 1/4" P: 83 dB(A)
–
Sound power level L
wA
measured according to
ISO 22868 for 3/8" P: 102 dB(A)
–
Sound power level L
wA
measured according to
ISO 22868 for 1/4" P: 96 dB(A)
Shaft fully compressed:
–
Vibration level a
hv
measured according to
ISO 22867
–
Control handle: 4.3 m/s²
–
Handle hose: 5.1 m/s²
Shaft fully extended:
–
Vibration level a
hv
measured according to
ISO 22867
–
Control handle: 4.1 m/s²
–
Handle hose: 5.6 m/s²
The vibration levels indicated were measured
according to a standardized test method and can
be used as a basis for comparing electric power
tools. The vibration levels actually occurring may
vary from the values indicated, depending on the
type of application. The vibration levels indicated
can be used for an initial estimate of the vibration
stress. The actual vibration stress has to be esti‐
mated. The times when the power tool is
switched off and the times when it is switched on
but running under no load can be taken into
account in the estimate.
For information on compliance with Employers'
Vibration Directive 2002/44/EC see
20.6
REACH
REACH is an EC regulation and stands for the
Registration, Evaluation, Authorisation and
Restriction of Chemical substances.
20 Specifications
English
0458-698-0121-B
23