![Stihl FS 240 Скачать руководство пользователя страница 101](http://html1.mh-extra.com/html/stihl/fs-240/fs-240_service-manual_1378617101.webp)
100
FS 240 C, FS 260 C, FS 360 C, FS 410 C, FS 460 C-M
Checking operation, versions
with M-Tronic
Lever (1) must align with the contact
surface (arrows) on the cam of
lever (2).
– Reassemble remaining parts in
reverse order
11.4.5 Choke lever/choke knob
– Remove the carburetor,
:
Remove choke knob (1) with a
firm tug
– choke knob is held in place by
the depression on the shaft
5904RA364 TG
2
1
5904RA365 TG
1
:
Remove spring (1)
:
Push out circlip (1)
:
Pull out lever (2) with torsion
spring (arrow)
– Remove torsion spring
Versions with M-Tronic
:
Push out circlip (1)
:
Pull out lever (2) with torsion
spring (arrow)
– Remove torsion spring
5904RA366 TG
1
5904RA367 TG
2
1
5904RA368 TG
1
2
Installation
All versions
:
Orient the torsion spring (1) so
that the angled end points toward
the carburetor
:
Slide torsion spring (1) onto the
choke shaft and slide the angled
end into the hole (arrow) – torsion
spring is secured
Versions without M-Tronic
:
Orient the lever (1) so that the flat
surface aligns with the choke
shaft (2) and the cam (3) faces
the throttle shaft lever
:
Slide lever (1) onto choke
shaft (2), turn torsion spring
counterclockwise and hook it into
lever (arrow)
5904RA369 TG
1
5904RA370 TG
1
2
3