15 Maintenance and Repairs
15.1
Maintenance Intervals
The maintenance intervals are dependent on the
environmental and operating conditions. STIHL
recommends the following maintenance inter‐
vals:
Every 12 months
► Have the blower checked by a STIHL servic‐
ing dealer.
15.2
Servicing and Repairing the
Blower
The blower cannot be serviced or repaired by the
user.
► If your blower has a malfunction or is dam‐
aged or requires servicing: Contact your
STIHL servicing dealer.
16 Troubleshooting
16.1
Troubleshooting the Blower and Battery
Fault
LEDs on the
battery
Cause
Remedy
The blower does
not start when
switched on.
1 LED flashing
green.
State of charge of the
battery is too low.
► Charge battery as described in the User
Manual for chargers STIHL AL 101, 301,
301-4, 500.
1 LED emits
red light.
The battery is too
warm or too cold.
► Pull the connecting cable plug out of the
socket.
► Allow the battery to cool down or warm
up.
3 LEDs flash
red.
There is a fault in the
blower.
► Pull connecting cable plug out of the
socket and plug it in again.
► Turn on the blower.
► If 3 LEDs continue to flash red: Do not
use the blower and contact your STIHL
dealer for assistance.
3 LEDs light up
red.
The blower is too
warm.
► Pull the connecting cable plug out of the
socket.
► Allow the blower to cool down.
4 LEDs flash‐
ing red.
There is a fault in the
battery.
► Pull connecting cable plug out of the
socket and plug it in again.
► Turn on the blower.
► If 4 LEDs continue to flash red: Do not
use the battery; contact a STIHL author‐
ized dealer.
No electrical contact
between the blower
and the battery.
► Pull connecting cable plug out of the
socket and plug it in again.
► If blower still does not start when
switched on: Clean contacts of connect‐
ing cable as described in the User Man‐
ual for the STIHL AR battery or the “AP
belt bag with connecting cable”.
The blower or the bat‐
tery is damp.
► Allow blower or battery to dry.
Trigger is pressed
before operating the
release slide.
► Turn on the blower as described in this
user manual.
The blower turns
off while in oper‐
ation.
3 LEDs light up
red.
The blower is too
warm.
► Pull the connecting cable plug out of the
socket.
► Allow the blower to cool down.
There is an electrical
fault.
► Pull connecting cable plug out of the
socket and plug it in again.
English
15 Maintenance and Repairs
14
0458-812-0121-B
Содержание BGA 200
Страница 1: ...BGA 200 2 16 Instruction Manual...
Страница 17: ...21 UKCA Declaration of Conformity English 0458 812 0121 B 17...
Страница 18: ...English 21 UKCA Declaration of Conformity 18 0458 812 0121 B...
Страница 19: ...21 UKCA Declaration of Conformity English 0458 812 0121 B 19...
Страница 20: ...www stihl com 04588120121B 04588120121B 0458 812 0121 B 0458 812 0121 B...