SpECial iNfOrmaTiON
w
ww.stiebel-eltron.com
WPE-I H(K)W 230 Premium |
3
SpECial iNfOrmaTiON
- The appliance may be used by children over
8 years of age and persons with reduced
physical, sensory or mental capabilities or a
lack of experience and expertise, provided
that they are supervised or they have been
instructed on how to use the appliance safe-
ly and have understood the potential risks.
Children must never play with the appliance.
Cleaning and user maintenance must not be
carried out by children without supervision.
- The connection to the power supply must
be in the form of a permanent connection.
Ensure the appliance can be separated from
the power supply by an isolator that discon-
nects all poles with at least 3 mm contact
separation.
- Maintain the minimum clearances to ensure
trouble-free operation of the appliance and
facilitate maintenance work.
- In dual mode operation, return water from
the second heat generator may flow through
the heat pump. Please note that the return
water temperature may be a maximum of
65 °C.
- Maintenance work, such as checking the elec-
trical safety, must only be carried out by a
qualified contractor.
- We recommend regular inspection (to es-
tablish the current condition of the system),
and maintenance by a qualified contractor if
required (to return the system to its original
condition).
- Following disconnection from the power sup-
ply, parts of the appliance may remain ener-
gised for 5 minutes until the inverter capaci-
tors have discharged.
- Never interrupt the power supply, even out-
side the heating season. The system's active
frost protection is not guaranteed if the power
supply is interrupted.
- There is no need to shut the system down in
summer. The heat pump manager has an au-
tomatic summer/winter changeover.
- Drain the DHW cylinder as described in chap-
ter "Installation / Maintenance / DHW cylin-
der / Draining the DHW cylinder".
- Install a type-tested safety valve in the cold
water supply line. Please note that, depending
on the supply pressure, you may also need a
pressure reducing valve.
- The safety valve drain aperture must remain
open to atmosphere.
- Install the safety valve drain pipe with a con-
stant fall to the drain.
- Size the drain pipe so that water can drain
off unimpeded when the safety valve is fully
opened.
WPE-I HKW 230 Premium
- The appliance is only suitable for passive
cooling.
- In the delivered condition, the COOLING pa-
rameter is set to OFF.
- The COOLING menu will only be displayed if a
FET is connected. Cooling mode is only possi-
ble in summer mode.
Содержание WPE-I 04 HKW 230 Premium
Страница 29: ...Installation Specification www stiebel eltron com WPE I H K W 230 Premium 29 ...
Страница 45: ...www stiebel eltron com WPE I H K W 230 Premium 45 NOTES ...
Страница 46: ...46 WPE I H K W 230 Premium www stiebel eltron com NOTES ...
Страница 47: ...www stiebel eltron com WPE I H K W 230 Premium 47 NOTES ...