STIEBEL ELTRON SNE 5 t ECO Скачать руководство пользователя страница 4

OpEraTiON 

 

appliance description

4

 | SNE 5 t ECO GB www.stiebel-eltron.com

2.2  General safety instructions

 

WARNING Burns

There is a risk of scalding at outlet temperatures in ex-

cess of 43 °C.

!

 

WARNING Injury

The appliance may be used by children aged 8 and older 

and persons with reduced physical, sensory or mental 

capabilities or a lack of experience and know-how, pro-

vided that they are supervised or they have been in-

structed on how to use the appliance safely and have 

understood the potential risks. Children must never play 

with the appliance. Children must never clean the ap-

pliance or perform user maintenance unless they are 

supervised.

Where children or persons with limited physical, sensory or men-

tal abilities are allowed to use this appliance, we recommend a 

permanent temperature limit (see chapter "Settings / Configura-

tion menu / Parameters / P1 | P2").

!

 

Material losses

The user should protect the appliance and its tap against 

frost.

!

 

Material losses

Never subject the appliance to water pressure. The tap 

outlet has a vent function. Scale build-up can block the 

outlet and subject the appliance to pressure.

f

f

Never seal the tap outlet.

f

f

Only use special aerators for non-pressurised water 

heaters.

f

f

Never extend the tap outlet with a hose.

2.3  Test symbols

See type plate on the appliance.

3.  Appliance description

This open vented (non-pressurised) appliance maintains the water 

content at the set temperature, in line with the pre-selected oper-

ating mode. The appliance may only be installed with taps for open 

vented (non-pressurised) water heaters (see chapter "Installation / 

Appliance description / Accessories").

Thermostop function

The thermostop function (thermal separation) prevents the tap 

becoming hot in standby mode.

Anti-drip function

The anti-drip function prevents expansion water from escaping 

from the tap during heating. When water is heated, gas bubbles 

are formed. The amount of gas bubbles depends on the water 

quality. At temperatures > 75 °C the rising gas bubbles can cause 

residual water to drip from the tap outlet.
Subject to design, some taps have a tendency to drip for a short 

while after being closed. This dripping is caused by residual water 

escaping from the tap outlet and is not linked to expansion water.

ECO mode with hygiene function

To save energy, the cylinder temperature is reduced by 15 °C in 

ECO mode and the temperature setting range is limited to between 

7 and 55 °C.
During ECO mode, the hygiene function inhibits the growth of 

bacteria. For this, the appliance heats the water content to 73 °C 

for 30 minutes once a week (Saturday nights).

 

WARNING Burns

There is a risk of scalding at outlet temperatures in ex-

cess of 43 °C.

 

Note

 

- Before activating ECO mode, you must first set the 

day of the week and the time.

 

- To activate/deactivate ECO mode, press and hold the 

"ECO" button for at least 1 second.

Timer mode

The appliance is equipped with an integrated time switch that 

enables timer mode. Three configurable time programs are avail-

able for this.

Содержание SNE 5 t ECO

Страница 1: ...OPERATION AND INSTALLATION Open vented non pressurised small water heater SNE 5 t ECO GB...

Страница 2: ...stallation Maintenance Draining the appliance SPECIAL INFORMATION OPERATION 1 General information 3 1 1 Safety instructions 3 1 2 Other symbols in this documentation 3 1 3 Units of measurement 3 2 Sa...

Страница 3: ...njury or death CAUTION Failure to observe this information may result in non seri ous or minor injury 1 2 Other symbols in this documentation Note General information is identified by the adjacent sym...

Страница 4: ...content at the set temperature in line with the pre selected oper ating mode The appliance may only be installed with taps for open vented non pressurised water heaters see chapter Installation Appli...

Страница 5: ...lation Troubleshooting Fault list Call your qualified contractor Green LED flashes The appliance was disconnected from the power sup ply for a long time approx 8 hours Reset the day and time 3 1 3 Dis...

Страница 6: ...symbol appears you can change the setting of the menu item with and Press OK to save the setting To exit the standard menu press Menu The standard display appears Note During initial start up and fol...

Страница 7: ...d weekly To configure a comfort phase in time program Pro3 proceed as follows f f In the configuration menu use and to call up time program Pro3 f f Press OK The display shows 3 f f Press OK The day o...

Страница 8: ...s Activating parameter P5 resets the appliance to the factory setting 5 Cleaning care and maintenance f f Never use abrasive or corrosive cleaning agents A damp cloth is sufficient for cleaning the ap...

Страница 9: ...INSTALLATION TEMPLATE...

Страница 10: ......

Страница 11: ...79 mm 140 mm 407mm 263mm 407mm 263mm D0000071802...

Страница 12: ...NOTES...

Страница 13: ...wing are delivered with the appliance Wall mounting bracket 8 2 Accessories 8 2 1 Required accessories The following taps are available as accessories for open vented operation Mixer taps WST WUT Mono...

Страница 14: ...with a fully opened tap see chapter Installation Specification Data table Match up the colour coding on the tap water connections and the appliance R h side blue Cold water inlet L h side red DHW outl...

Страница 15: ...iance carries out a new boil dry protection check f f If the fault continues to be displayed reset the appliance P5 on 11 1 1 Appliance handover f f Explain the functions of the appliance to the user...

Страница 16: ...replace the strainer 14 3 Opening the appliance Material losses Incorrect handling can damage the BUS connection be tween the programming unit and the main PCB f f Carefully pivot the appliance cover...

Страница 17: ...e power cable The power cable must only be replaced by a qualified contractor with an original spare part D0000071890 f f Route the power cable along the cable guide 14 7 Positioning the temperature s...

Страница 18: ...Energy conversion efficiency 38 Annual power consumption kWh 489 Default temperature setting C 55 Sound power level dB A 15 Daily power consumption kWh 2 260 15 7 Data table SNE 5 t ECO GB 202135 Hydr...

Страница 19: ...those subsidiaries Such guarantee is only grant ed if the subsidiary has issued its own terms of guarantee No other guarantee will be granted We shall not provide any guarantee for appliances acquire...

Страница 20: ...Finland STIEBEL ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387...

Отзывы: