STIEBEL ELTRON SNE 5 t ECO Скачать руководство пользователя страница 18

iNSTallaTiON 

 

Specification

14

 | SNE 5 t ECO GB www.stiebel-eltron.com

15.3  Heat-up diagram

The heat-up period depends on the degree of scaling and residual 

heat. For the heat-up time for a cold water supply at 10 °C and a 

maximum temperature setting, see the diagram.

35

30

40

45

50

55

60

65

70

75

80

85

0

5

10

15

D

00000

77

59

7

x  Temperature in °C

y  Duration in min

15.4  Country-specific approvals and certifications

See the type plate for test symbols.

15.5  Extreme operating and fault conditions

In the case of faults, a peak temperature of up to 100 °C may briefly 

occur in the system.

15.6  Energy consumption data

Product datasheet: Conventional water heaters to regulation (EU) 

no. 812/2013 and 814/2013

 

 

SNE 5 t ECO GB

 

 

202135

Manufacturer

 

STIEBEL ELTRON

Load profile

 

XXS

Energy efficiency class

 

A

Energy conversion efficiency

%

38

Annual power consumption

kWh

489

Default temperature setting

°C

55

Sound power level

dB(A)

15

Daily power consumption

kWh

2.260

15.7  Data table

 

 

SNE 5 t ECO GB

 

 

202135

Hydraulic data
Rated capacity

l

5

Mixed water volume at 40 °C

l

10

Electrical details
Rated voltage

V

220

230

240

Rated output

kW

1.8

2

2.2

Rated current

A

8.3

8.7

9.1

Fuse protection

A

10

Phases

 

1/N/PE

Frequency

Hz

50/60

Power supply

 

1/N/PE

Application limits
Available temperature range

°C

30 - 85

Max. permissible pressure

MPa

0

Max. throughput

l/min

5

Energy data
Standby energy consumption / 24h at 38 °C

kWh

0.09

Standby energy consumption / 24 h at 65 °C

kWh

0.2

Energy efficiency class

 

A

Versions
IP-Rating

 

IP24 D

Type of installation

 

Undersink

Type

 

open

Material, internal cylinder

 

PP

Thermal insulation material

 

EPS

Casing material

 

ASA

Colour

 

white

Connections
Water connection

 

G 3/8 A

Dimensions
Height

mm

421

Width

mm

263

Depth

mm

230

Length of connecting cable

mm

600

Weights
Weight

kg

3.1

Содержание SNE 5 t ECO

Страница 1: ...OPERATION AND INSTALLATION Open vented non pressurised small water heater SNE 5 t ECO GB...

Страница 2: ...stallation Maintenance Draining the appliance SPECIAL INFORMATION OPERATION 1 General information 3 1 1 Safety instructions 3 1 2 Other symbols in this documentation 3 1 3 Units of measurement 3 2 Sa...

Страница 3: ...njury or death CAUTION Failure to observe this information may result in non seri ous or minor injury 1 2 Other symbols in this documentation Note General information is identified by the adjacent sym...

Страница 4: ...content at the set temperature in line with the pre selected oper ating mode The appliance may only be installed with taps for open vented non pressurised water heaters see chapter Installation Appli...

Страница 5: ...lation Troubleshooting Fault list Call your qualified contractor Green LED flashes The appliance was disconnected from the power sup ply for a long time approx 8 hours Reset the day and time 3 1 3 Dis...

Страница 6: ...symbol appears you can change the setting of the menu item with and Press OK to save the setting To exit the standard menu press Menu The standard display appears Note During initial start up and fol...

Страница 7: ...d weekly To configure a comfort phase in time program Pro3 proceed as follows f f In the configuration menu use and to call up time program Pro3 f f Press OK The display shows 3 f f Press OK The day o...

Страница 8: ...s Activating parameter P5 resets the appliance to the factory setting 5 Cleaning care and maintenance f f Never use abrasive or corrosive cleaning agents A damp cloth is sufficient for cleaning the ap...

Страница 9: ...INSTALLATION TEMPLATE...

Страница 10: ......

Страница 11: ...79 mm 140 mm 407mm 263mm 407mm 263mm D0000071802...

Страница 12: ...NOTES...

Страница 13: ...wing are delivered with the appliance Wall mounting bracket 8 2 Accessories 8 2 1 Required accessories The following taps are available as accessories for open vented operation Mixer taps WST WUT Mono...

Страница 14: ...with a fully opened tap see chapter Installation Specification Data table Match up the colour coding on the tap water connections and the appliance R h side blue Cold water inlet L h side red DHW outl...

Страница 15: ...iance carries out a new boil dry protection check f f If the fault continues to be displayed reset the appliance P5 on 11 1 1 Appliance handover f f Explain the functions of the appliance to the user...

Страница 16: ...replace the strainer 14 3 Opening the appliance Material losses Incorrect handling can damage the BUS connection be tween the programming unit and the main PCB f f Carefully pivot the appliance cover...

Страница 17: ...e power cable The power cable must only be replaced by a qualified contractor with an original spare part D0000071890 f f Route the power cable along the cable guide 14 7 Positioning the temperature s...

Страница 18: ...Energy conversion efficiency 38 Annual power consumption kWh 489 Default temperature setting C 55 Sound power level dB A 15 Daily power consumption kWh 2 260 15 7 Data table SNE 5 t ECO GB 202135 Hydr...

Страница 19: ...those subsidiaries Such guarantee is only grant ed if the subsidiary has issued its own terms of guarantee No other guarantee will be granted We shall not provide any guarantee for appliances acquire...

Страница 20: ...Finland STIEBEL ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387...

Отзывы: