EN
GL
ISH
www.stiebel-eltron.com
SHC 10 | SHC 15 |
9
INSTALLATION
Maintenance
13.1 Activate high limit safety cut-out
f
f
Open the appliance (see chapter "Installation / Maintenance /
Opening the appliance").
f
f
Pull off the adaptor.
f
f
Press the reset button on the high limit safety cut-out.
f
f
Fit the adaptor.
f
f
Close the appliance cover.
f
f
Fit the limiting ring and temperature selector.
1
2
D
00000
39
37
2
1 Adaptor
2 Reset button, high limit safety cut-out
14. Maintenance
WARNING ELECTROCUTION
Before any work on the appliance, disconnect all poles of
the appliance from the power supply.
f
f
Dismantle the appliance for maintenance work.
14.1 Checking the safety valve
f
f
Check the function of the safety valve regularly.
14.2 Draining the appliance
WARNING Burns
Hot water may escape during the draining process.
f
f
Drain the appliance via its connectors.
14.3 Opening the appliance
D
00000
39
37
4
f
f
Pull off the temperature selector and the limiting ring.
f
f
Remove the 4 screws from the casing.
f
f
Open the appliance cover by pivoting the cover upwards and
then removing it.
f
f
Remove the upper insulation semi-shell if required.
14.4 Removing the flanged immersion heater and
temperature controller / high limit safety cut-
out
D
00000
39
37
9
1
2
1 Flanged immersion heater
2 Combined temperature controller / high limit safety cut-out
f
f
Disconnect all wires from the combined temperature control-
ler/high limit safety cut-out.
f
f
Remove the combined temperature controller / high limit
safety cut-out from the flanged immersion heater.
f
f
Remove the flanged immersion heater.