4. Cleaning, care and maintenance
f
f
Never use abrasive or corrosive cleaning agents. A damp
cloth is sufficient for cleaning the appliance.
f
f
Check the taps regularly. Limescale deposits at the tap out-
lets can be removed using commercially available descaling
agents.
f
f
Regularly activate the safety valve to prevent it from becom-
ing blocked, e.g. by limescale deposits.
f
f
Have the protective anode checked by a qualified contractor
after the first 2 years of operation. The qualified contractor
will then determine the intervals at which it must be checked
thereafter.
Almost every type of water will deposit limescale at high temper-
atures. This settles inside the appliance and affects both the per-
formance and service life. The heating element should therefore
be descaled if necessary. A qualified contractor who is aware of
the local water quality will tell you when the next descaling is due.
5. Troubleshooting
Problem
Cause
Remedy
The appliance does not
supply hot water.
The temperature
selector is set
to "*".
Switch the appliance ON by turning
the temperature selector.
No power at the
appliance.
Check the plug / fuses in the fuse
box.
Water can only be
drawn at a reduced
rate.
The aerator in
the tap is scaled
up or dirty.
Descale / replace the aerator.
Loud boiling noises in-
side the appliance.
The appliance is
scaled up.
Have the appliance descaled by a
qualified contractor.
Water drips from the
safety valve after
heat-up.
The safety valve
is scaled up or
dirty.
Switch the appliance off. Depressur-
ise the appliance by disconnecting
it from the power and water supply.
Have the safety valve checked by a
qualified contractor.
If you cannot remedy the fault, notify your qualified contractor.
To facilitate and speed up your enquiry, please provide the serial
number from the type plate. (000000):
F-No.
O-No.
0000 - 000000
000000
D
00000
39
38
2
INSTALLATION
6. Safety
Only a qualified contractor should carry out installation, commis-
sioning, maintenance and repair of the appliance.
6.1 General safety instructions
We guarantee trouble-free function and operational reliability only
if original accessories and spare parts intended for the appliance
are used.
6.2 Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
7. Appliance description
The sealed unvented (pressurised) appliance is only suitable for
undersink installation. The appliance is intended for heating cold
water and to supply one or several draw-off points.
The appliance may only be installed with pressure taps in con-
junction with a type-tested safety valve (see chapter “Installation /
Appliance description / Standard delivery”).
The type-tested safety valve protects the appliance against unac-
ceptable excess pressure.
The enamelled internal steel cylinder is equipped with a protective
anode. The protective anode protects the inner cylinder against
corrosion.
7.1 Standard delivery
The following are delivered with the appliance:
- Wall mounting bracket
SHC 10 | SHC 15 Stiebel
- Two reducers from G 1/2 to G 3/8
SHC 10 GB Eltron | SHC 15 GB Eltron
- Two locking ring fittings G 1/2 x 15
7.2 Accessories
SHC 10 | SHC 15 Stiebel
- Safety assembly G 1/2 (optional)