STIEBEL ELTRON DHE 18 AU Скачать руководство пользователя страница 8

OpErATiON 

 

Cleaning, care and maintenance

8

 | DHE  AU 

www.stiebel-eltron.com

menu Description

Selectable display | 

setting

Explanations

Symbol | 

display

P 11 

 

 

Resetting the consump-

tion values 

 

Reset (

 |  ) 

 

 

You can reset the consumption values. "rSEt" is shown on the display.

 

f

Press "1" and "2" simultaneously and hold for longer than 5 sec-

onds. The display switches to "On" to confirm the reset.

 

f

To confirm "On", press and hold "i" for more than 5 seconds.

 

 

 

P 12 

 

 

 

Backlighting 

 

 

 

Auto | On 

 

 

 

You can adjust the display backlight. 

 

- If "Auto" is selected, the backlight is switched on during heating 

operation and each time an action is performed. If no action is per-

formed for 30 seconds, the backlight is switched off again.

 

- If you select "On", the backlight will remain on constantly. 

  

 

 

 

P 13

Reduce backlighting

100 % | 20 % (

)

You can select 2 levels of brightness for the backlight.

 

P 14 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wireless module 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

After installation of a wireless module (with or without paired wire-

less remote control) in the appliance, menu item P 14 is enabled and 

"rc" appears on the programming unit display. You can pair one or 

more wireless remote controls; to do so, follow the pairing procedure 

on the appliance and the wireless remote control.  

Pressing "1" on the appliance for longer than 5 seconds starts the 

pairing process, which is shown on the programming unit of the ap-

pliance by a progress bar on the display and the operating LED flash-

ing. Start the pairing process on the wireless remote control as de-

scribed in the relevant operating instructions. After successful pairing, 

the operating LED on the appliance flashes briefly. An unsuccessful 

pairing attempt is automatically terminated after 30 seconds.  

Pressing "2" on the appliance for longer than 5 seconds unpairs all 

connected wireless remote controls. During unpairing, "rc0" appears 

on the display of the programming unit for 5 seconds, then "rc" again.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.9.3  Deactivating the parameter menu

f

f

Exit the menu item by pressing "i" and holding for more than 

5 seconds. Alternatively: The system exits the menu item au-

tomatically 30 seconds after the setting has been completed.

4.10  Recommended settings

Your instantaneous water heater offers maximum precision and 

maximum convenience in DHW provision. Should you nonetheless 

operate the appliance with a thermostatic valve, we recommend 

that you:

f

f

Adjust the set temperature on the appliance to over 50 °C. 

Then set the required set temperature on the thermostatic 

valve.

Saving energy

The following recommended settings will result in the lowest en-

ergy consumption:

 

- 38 °C for hand washbasins, showers, bath

 

- 55 °C for kitchen sinks

Internal anti-scalding protection (qualified contractors)

If required, the qualified contractor can set a permanent temper-

ature limit, for example in nurseries, hospitals, etc. 

Recommended setting for operation with a thermostatic valve 

and water preheated by solar energy

f

f

Set the temperature at the instantaneous water heater to the 

maximum temperature.

Following an interruption to the water supply

!

 

Material losses

To ensure that the bare wire heating system is not dam-

aged following an interruption to the water supply, the 

appliance must be recommissioned by taking the follow-

ing steps.

f

f

Disconnect the appliance from the power supply by 

removing the fuses/tripping the MCBs.

f

f

Open the tap for one minute until the appliance and 

its upstream cold water inlet line are free of air.

f

f

Switch on the power supply again.

5.  Cleaning, care and maintenance

f

f

Never use abrasive or corrosive cleaning agents. A damp 

cloth is sufficient for cleaning the appliance.

f

f

Check the taps regularly. Limescale deposits at the tap out-

lets can be removed using commercially available descaling 

agents.

Содержание DHE 18 AU

Страница 1: ...OPERATION AND INSTALLATION Fully electronically controlled comfort instantaneous water heater DHE 18 AU DHE 27 AU...

Страница 2: ...ery 10 8 2 Accessories 10 9 Preparation 10 9 1 Installation site 10 9 2 Minimum clearances 10 9 3 Water installation 10 10 Installation 11 10 1 Standard installation 11 11 Commissioning 13 11 1 Prepar...

Страница 3: ...e to 43 C using the internal anti scalding protection on the ap pliance When using preheated water ensure that the inlet temperature does not exceed 55 C In Australia the use of a temperature control...

Страница 4: ...efully Symbol Meaning Material losses appliance damage consequential losses and environmen tal pollution Appliance disposal f f This symbol indicates that you have to do something The ac tion you need...

Страница 5: ...to the selected temperature This occurs regardless of the inlet temperature If the appliance is operated with preheated water and the inlet temperature exceeds the selected temperature the inlet temp...

Страница 6: ...perature flashes once to confirm 4 7 Inlet temperature information If the appliance is operated with preheated water and the inlet temperature exceeds the selected set temperature the inlet tem peratu...

Страница 7: ...sec 4 Circulation boost program Shower your arms and legs with cold water to boost circulation Spray from the hands and feet towards the body You can then repeat this process with hot water WW KW 3 m...

Страница 8: ...mote controls During unpairing rc0 appears on the display of the programming unit for 5 seconds then rc again 4 9 3 Deactivating the parameter menu f f Exit the menu item by pressing i and holding for...

Страница 9: ...and repair of the appliance 7 1 General safety instructions We guarantee trouble free function and operational reliability only if original accessories and spare parts intended for the appliance are...

Страница 10: ...n D0000056242 1 2 1 Cold water inlet 2 DHW outlet Oversink installation D0000057030 1 2 1 Cold water inlet 2 DHW outlet Note f f Mount the appliance on the wall The wall must have sufficient load bear...

Страница 11: ...r back panel section forwards Preparing the power cable on unfinished walls for connection from below 160 30 D0000053273 1 1 Cable entry installation aid f f Prepare the power cable Fitting the wall m...

Страница 12: ...outlet pipe from the pipework with flat gaskets to the extensions from the appliance Making the electrical connection WARNING Electrocution Carry out all electrical connection and installation work in...

Страница 13: ...over should be turned the other way up for easier operation see chapter Installation alternatives Rotated appliance cover Fit the appliance cover D0000040777 1 2 3 4 1 Pipe knock out 2 Cover guides 3...

Страница 14: ...ed from below short power cable IP 25 Finished walls IP 24 Water connection IP rating Unfinished walls IP 25 Other IP rating Installation with offset tiles IP 25 Rotated appliance cover IP 25 Horizont...

Страница 15: ...ns Deburr any sharp edges with a file f f Route the power cable through the cable grommet f f Connect the power cable to the mains terminal 13 4 Water installation on unfinished walls 12 D0000053319 f...

Страница 16: ...ersink installation D0000073012 f f Remove the programming unit from the appliance cover by pressing the locking hooks and removing the programming unit f f Turn the appliance cover not the appliance...

Страница 17: ...e appliance cover must be provided with a condensate drain opening of min 5 0 mm to max 6 0 mm at the marked po sition 50 5 0 D0000076914 1 2 1 Appliance cover with opening for condensate drain 2 Back...

Страница 18: ...atch set value Tap faulty Replace tap Outlet sensor faulty Replace outlet sensor Heating system faulty Replace the function module PCB faulty Replace the function module Green flashes yellow flashes r...

Страница 19: ...e can freeze and cause damage Clean strainer If the strainer in the threaded cold water fitting is dirty clean it Close the shut off valve in the cold water inlet line before remov ing cleaning and re...

Страница 20: ...l min Rated voltage Cold water inlet temperature 380 V 400 V 415 V 5 C 10 C 15 C 20 C DHE 18 AU 16 2 5 1 5 8 6 6 7 7 18 0 5 7 6 4 7 3 8 6 19 4 6 2 6 9 7 9 9 2 DHE 27 AU 23 5 7 5 8 4 9 6 11 2 26 0 8 3...

Страница 21: ...city l 0 4 0 4 Versions Adjustable connected load Temperature settings C Off 20 60 Off 20 60 Protection class 1 1 Insulating block Plastic Plastic Heating system heat generator Bare wire Bare wire Cov...

Страница 22: ...t was not installed and commissioned a in Australia b in accordance with the Operating and Installation Guide and c in accordance with the relevant statutory and local require ments of the State or Te...

Страница 23: ...ENGLISH www stiebel eltron com DHE AU 23 NOTES...

Страница 24: ...TIEBEL ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88 F...

Отзывы: