STIEBEL ELTRON DHE 18 AU Скачать руководство пользователя страница 6

OpErATiON 

 

Settings and displays

6

 | DHE  AU 

www.stiebel-eltron.com

4.3  Selecting the set temperature

D

00000

91

07

9

2

1

1  Set temperature settings: OFF, 20 - 60 °C

2  To call up/assign preferred temperatures

Settings

Setting

Step

Setting

Step

20 °C ... 60 °C 

0.5 °C

68 °F ... 140 °F

1 °F

4.4  Temperature limit via internal anti-scalding 

protection (qualified contractor)

If required, the qualified contractor can set a permanent temper-

ature limit, for example in nurseries, hospitals, etc. 
If the anti-scalding protection function is enabled and the tem-

perature limit is reached, "Tmax" flashes.

4.5  Temperature limit Tmax (user)

You can adjust the temperature limit individually. If the tempera-

ture limit is enabled, "Tmax" is shown on the display.

4.5.1  Activating/deactivating the temperature limit Tmax

See chapter "Settings in the parameter menu".

4.6  Assigning temperature memory buttons

Memory buttons "1" and "2" can each be assigned a preferred 

temperature.

f

f

Select the preferred temperature.

f

f

To save the preferred temperature, press and hold button 

"1" or "2" for more than 3 seconds. The selected temperature 

flashes once to confirm.

4.7  Inlet temperature information

If the appliance is operated with preheated water and the inlet 

temperature exceeds the selected set temperature, the inlet tem-

perature is indicated on the second display line and flashes. The 

water is not heated further.

4.8  Info menu

The appliance has an additional display where consumption values 

can be shown.

4.8.1  Calling up the info menu

f

f

Briefly press "i" until "i 1" appears, then continue to press "i" 

to see further menus.

f

f

Exit the menu item by pressing "i" and holding for more than 

5 seconds. Alternatively: The system exits the menu item au-

tomatically 30 seconds after the setting has been completed.

menu Description

Explanations

Screen | display

I 1 

Flow rate 

The current flow rate 

is shown.

Flow rate in l/min or 

gpm

I 2 

Time 

The current time is 

shown.

Time 

I 3 

 

Energy consump-

tion 

The amount of en-

ergy consumed is 

shown.

Value in kWh 

 

I 4 

Water consump-

tion

The amount of water 

consumed is shown.

Value in m³ or gal 

4.9  Settings in the parameter menu

4.9.1  Activating the parameter menu

f

f

Briefly press and hold "i" for more than 5 seconds until "P 1" 

appears, then continue by briefly pressing "i".

f

f

In the selected parameter menu, turn the temperature selec-

tor to the required display / setting.

Содержание DHE 18 AU

Страница 1: ...OPERATION AND INSTALLATION Fully electronically controlled comfort instantaneous water heater DHE 18 AU DHE 27 AU...

Страница 2: ...ery 10 8 2 Accessories 10 9 Preparation 10 9 1 Installation site 10 9 2 Minimum clearances 10 9 3 Water installation 10 10 Installation 11 10 1 Standard installation 11 11 Commissioning 13 11 1 Prepar...

Страница 3: ...e to 43 C using the internal anti scalding protection on the ap pliance When using preheated water ensure that the inlet temperature does not exceed 55 C In Australia the use of a temperature control...

Страница 4: ...efully Symbol Meaning Material losses appliance damage consequential losses and environmen tal pollution Appliance disposal f f This symbol indicates that you have to do something The ac tion you need...

Страница 5: ...to the selected temperature This occurs regardless of the inlet temperature If the appliance is operated with preheated water and the inlet temperature exceeds the selected temperature the inlet temp...

Страница 6: ...perature flashes once to confirm 4 7 Inlet temperature information If the appliance is operated with preheated water and the inlet temperature exceeds the selected set temperature the inlet tem peratu...

Страница 7: ...sec 4 Circulation boost program Shower your arms and legs with cold water to boost circulation Spray from the hands and feet towards the body You can then repeat this process with hot water WW KW 3 m...

Страница 8: ...mote controls During unpairing rc0 appears on the display of the programming unit for 5 seconds then rc again 4 9 3 Deactivating the parameter menu f f Exit the menu item by pressing i and holding for...

Страница 9: ...and repair of the appliance 7 1 General safety instructions We guarantee trouble free function and operational reliability only if original accessories and spare parts intended for the appliance are...

Страница 10: ...n D0000056242 1 2 1 Cold water inlet 2 DHW outlet Oversink installation D0000057030 1 2 1 Cold water inlet 2 DHW outlet Note f f Mount the appliance on the wall The wall must have sufficient load bear...

Страница 11: ...r back panel section forwards Preparing the power cable on unfinished walls for connection from below 160 30 D0000053273 1 1 Cable entry installation aid f f Prepare the power cable Fitting the wall m...

Страница 12: ...outlet pipe from the pipework with flat gaskets to the extensions from the appliance Making the electrical connection WARNING Electrocution Carry out all electrical connection and installation work in...

Страница 13: ...over should be turned the other way up for easier operation see chapter Installation alternatives Rotated appliance cover Fit the appliance cover D0000040777 1 2 3 4 1 Pipe knock out 2 Cover guides 3...

Страница 14: ...ed from below short power cable IP 25 Finished walls IP 24 Water connection IP rating Unfinished walls IP 25 Other IP rating Installation with offset tiles IP 25 Rotated appliance cover IP 25 Horizont...

Страница 15: ...ns Deburr any sharp edges with a file f f Route the power cable through the cable grommet f f Connect the power cable to the mains terminal 13 4 Water installation on unfinished walls 12 D0000053319 f...

Страница 16: ...ersink installation D0000073012 f f Remove the programming unit from the appliance cover by pressing the locking hooks and removing the programming unit f f Turn the appliance cover not the appliance...

Страница 17: ...e appliance cover must be provided with a condensate drain opening of min 5 0 mm to max 6 0 mm at the marked po sition 50 5 0 D0000076914 1 2 1 Appliance cover with opening for condensate drain 2 Back...

Страница 18: ...atch set value Tap faulty Replace tap Outlet sensor faulty Replace outlet sensor Heating system faulty Replace the function module PCB faulty Replace the function module Green flashes yellow flashes r...

Страница 19: ...e can freeze and cause damage Clean strainer If the strainer in the threaded cold water fitting is dirty clean it Close the shut off valve in the cold water inlet line before remov ing cleaning and re...

Страница 20: ...l min Rated voltage Cold water inlet temperature 380 V 400 V 415 V 5 C 10 C 15 C 20 C DHE 18 AU 16 2 5 1 5 8 6 6 7 7 18 0 5 7 6 4 7 3 8 6 19 4 6 2 6 9 7 9 9 2 DHE 27 AU 23 5 7 5 8 4 9 6 11 2 26 0 8 3...

Страница 21: ...city l 0 4 0 4 Versions Adjustable connected load Temperature settings C Off 20 60 Off 20 60 Protection class 1 1 Insulating block Plastic Plastic Heating system heat generator Bare wire Bare wire Cov...

Страница 22: ...t was not installed and commissioned a in Australia b in accordance with the Operating and Installation Guide and c in accordance with the relevant statutory and local require ments of the State or Te...

Страница 23: ...ENGLISH www stiebel eltron com DHE AU 23 NOTES...

Страница 24: ...TIEBEL ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88 F...

Отзывы: