STIEBEL ELTRON DHE 18 AU Скачать руководство пользователя страница 19

iNSTAllATiON 

 

maintenance

EN

GL

ISH

www.stiebel-eltron.com 

DHE  AU | 

19

16.  Maintenance

 

WARNING Electrocution

Before any work on the appliance, disconnect all poles 

from the power supply.

This appliance contains capacitors which are discharged 

when disconnected from the power supply. The capacitor 

discharge voltage may briefly exceed 60 V DC.

Draining the appliance

The appliance can be drained for maintenance work.

 

WARNING Burns

Hot water may escape when you drain the appliance.

f

f

Close the shut-off valve in the cold water inlet line.

f

f

Open all draw-off valves.

f

f

Undo the pipe connections from the appliance.

f

f

Store the dismantled appliance free from the risk of frost, as 

water residues remaining inside the appliance can freeze and 

cause damage.

Clean strainer

If the strainer in the threaded cold water fitting is dirty, clean it. 

Close the shut-off valve in the cold water inlet line before remov-

ing, cleaning and refitting the strainer.

D

00000

77

74

0

2

1

1 Strainer

2  Plastic profile washer

f

f

Remove the plastic profile washer and the strainer. 

f

f

Clean the components.

f

f

Fit the strainer and the plastic profile washer.

17.  Specification

17.1  Dimensions and connections

466

481

225

35

35

414

38

105

≤ 20

140

30

b02

100

c01

c06

368

116

D

00000

77

73

9

 

 

DHE AU  

b02  Entry for electrical cables I

Unfinished walls

  

c01  Cold water inlet

Male thread

G 1/2 A

c06  DHW outlet

Male thread

G 1/2 A

Alternative connection options

165

b04

b04

69

330

b04

69

325

b04

b04

b03

20

35

30

b02

D

00000

77

73

6

 

 

DHE AU

b02  Entry for electrical cables I

Unfinished walls

  

b03  Entry for electrical cables II

Unfinished walls

  

b04  Entry electrical cables III

Finished walls

  

Содержание DHE 18 AU

Страница 1: ...OPERATION AND INSTALLATION Fully electronically controlled comfort instantaneous water heater DHE 18 AU DHE 27 AU...

Страница 2: ...ery 10 8 2 Accessories 10 9 Preparation 10 9 1 Installation site 10 9 2 Minimum clearances 10 9 3 Water installation 10 10 Installation 11 10 1 Standard installation 11 11 Commissioning 13 11 1 Prepar...

Страница 3: ...e to 43 C using the internal anti scalding protection on the ap pliance When using preheated water ensure that the inlet temperature does not exceed 55 C In Australia the use of a temperature control...

Страница 4: ...efully Symbol Meaning Material losses appliance damage consequential losses and environmen tal pollution Appliance disposal f f This symbol indicates that you have to do something The ac tion you need...

Страница 5: ...to the selected temperature This occurs regardless of the inlet temperature If the appliance is operated with preheated water and the inlet temperature exceeds the selected temperature the inlet temp...

Страница 6: ...perature flashes once to confirm 4 7 Inlet temperature information If the appliance is operated with preheated water and the inlet temperature exceeds the selected set temperature the inlet tem peratu...

Страница 7: ...sec 4 Circulation boost program Shower your arms and legs with cold water to boost circulation Spray from the hands and feet towards the body You can then repeat this process with hot water WW KW 3 m...

Страница 8: ...mote controls During unpairing rc0 appears on the display of the programming unit for 5 seconds then rc again 4 9 3 Deactivating the parameter menu f f Exit the menu item by pressing i and holding for...

Страница 9: ...and repair of the appliance 7 1 General safety instructions We guarantee trouble free function and operational reliability only if original accessories and spare parts intended for the appliance are...

Страница 10: ...n D0000056242 1 2 1 Cold water inlet 2 DHW outlet Oversink installation D0000057030 1 2 1 Cold water inlet 2 DHW outlet Note f f Mount the appliance on the wall The wall must have sufficient load bear...

Страница 11: ...r back panel section forwards Preparing the power cable on unfinished walls for connection from below 160 30 D0000053273 1 1 Cable entry installation aid f f Prepare the power cable Fitting the wall m...

Страница 12: ...outlet pipe from the pipework with flat gaskets to the extensions from the appliance Making the electrical connection WARNING Electrocution Carry out all electrical connection and installation work in...

Страница 13: ...over should be turned the other way up for easier operation see chapter Installation alternatives Rotated appliance cover Fit the appliance cover D0000040777 1 2 3 4 1 Pipe knock out 2 Cover guides 3...

Страница 14: ...ed from below short power cable IP 25 Finished walls IP 24 Water connection IP rating Unfinished walls IP 25 Other IP rating Installation with offset tiles IP 25 Rotated appliance cover IP 25 Horizont...

Страница 15: ...ns Deburr any sharp edges with a file f f Route the power cable through the cable grommet f f Connect the power cable to the mains terminal 13 4 Water installation on unfinished walls 12 D0000053319 f...

Страница 16: ...ersink installation D0000073012 f f Remove the programming unit from the appliance cover by pressing the locking hooks and removing the programming unit f f Turn the appliance cover not the appliance...

Страница 17: ...e appliance cover must be provided with a condensate drain opening of min 5 0 mm to max 6 0 mm at the marked po sition 50 5 0 D0000076914 1 2 1 Appliance cover with opening for condensate drain 2 Back...

Страница 18: ...atch set value Tap faulty Replace tap Outlet sensor faulty Replace outlet sensor Heating system faulty Replace the function module PCB faulty Replace the function module Green flashes yellow flashes r...

Страница 19: ...e can freeze and cause damage Clean strainer If the strainer in the threaded cold water fitting is dirty clean it Close the shut off valve in the cold water inlet line before remov ing cleaning and re...

Страница 20: ...l min Rated voltage Cold water inlet temperature 380 V 400 V 415 V 5 C 10 C 15 C 20 C DHE 18 AU 16 2 5 1 5 8 6 6 7 7 18 0 5 7 6 4 7 3 8 6 19 4 6 2 6 9 7 9 9 2 DHE 27 AU 23 5 7 5 8 4 9 6 11 2 26 0 8 3...

Страница 21: ...city l 0 4 0 4 Versions Adjustable connected load Temperature settings C Off 20 60 Off 20 60 Protection class 1 1 Insulating block Plastic Plastic Heating system heat generator Bare wire Bare wire Cov...

Страница 22: ...t was not installed and commissioned a in Australia b in accordance with the Operating and Installation Guide and c in accordance with the relevant statutory and local require ments of the State or Te...

Страница 23: ...ENGLISH www stiebel eltron com DHE AU 23 NOTES...

Страница 24: ...TIEBEL ELTRON OY Kapinakuja 1 04600 M nts l Tel 020 720 9988 info stiebel eltron fi www stiebel eltron fi France STIEBEL ELTRON SAS 7 9 rue des Selliers B P 85107 57073 Metz C dex 3 Tel 0387 7438 88 F...

Отзывы: