STIEBEL ELTRON DHE 18 AU Скачать руководство пользователя страница 14

iNSTAllATiON 

 

Appliance shutdown

14

 | DHE  AU 

www.stiebel-eltron.com

D

000

00

53

28

1

f

f

Switch on the power supply.

11.2.1  Appliance handover

f

f

Explain the appliance function to users and familiarise them 

with how it works.

f

f

Make the user aware of potential dangers, especially the risk 

of scalding. 

f

f

Hand over the instructions.

11.3  Recommissioning

!

 

Material losses

To ensure that the bare wire heating system is not dam-

aged following an interruption to the water supply, the 

appliance must be recommissioned by taking the follow-

ing steps.

f

f

Disconnect the appliance from the power supply by 

removing the fuses/tripping the MCBs.

f

f

Open the tap for at least one minute until the appli-

ance and its upstream cold water inlet line are free 

of air.

f

f

Switch on the power supply again.

12.  Appliance shutdown

f

f

Isolate all poles of the appliance from the power supply.

f

f

Drain the appliance (see chapter "Maintenance / Draining the 

appliance").

13.  Installation alternatives

Overview of installation alternatives

Electrical connection

ip rating

On unfinished walls, connected from above

IP 25

On unfinished walls, connected from below, short 

power cable

IP 25 

Finished walls

IP 24

Water connection

ip rating

Unfinished walls

IP 25

Other

ip rating

Installation with offset tiles

IP 25

Rotated appliance cover

IP 25

Horizontal installation of the appliance

IP 24

 

WARNING Electrocution

Before any work on the appliance, disconnect all poles 

from the power supply.

13.1  Electrical connection from above on unfinished 

walls

140

30

D

00000

76

50

7

1

1  Cable entry installation aid

f

f

Prepare the power cable.

D

00000

53

28

2

1

1  Cable routing

f

f

Reposition the mains terminal from the bottom to the top. To 

do this, undo the fixing screw. Turn the mains terminal with 

connecting cables 180° clockwise. Route the cable around 

the cable guide when doing so. Secure the mains terminal in 

place.

f

f

Replace the cable grommets.

f

f

Install the cable grommet from the top at the bottom.

f

f

Pull the cable grommet over the cable sheath of the power 

cable.

f

f

Install the appliance on the threaded studs of the wall 

mounting bracket.

f

f

Push the back panel firmly against the wall. Lock the fixing 

toggle by turning it 90° clockwise.

f

f

Pull the cable grommets into the back panel until both lock-

ing tabs engage.

f

f

Connect the power cable to the mains terminal.

 

WARNING Electrocution

The connecting wires must not protrude beyond the level 

of the mains terminal.

Содержание DHE 18 AU

Страница 1: ...OPERATION AND INSTALLATION Fully electronically controlled comfort instantaneous water heater DHE 18 AU DHE 27 AU...

Страница 2: ...ery 10 8 2 Accessories 10 9 Preparation 10 9 1 Installation site 10 9 2 Minimum clearances 10 9 3 Water installation 10 10 Installation 11 10 1 Standard installation 11 11 Commissioning 13 11 1 Prepar...

Страница 3: ...e to 43 C using the internal anti scalding protection on the ap pliance When using preheated water ensure that the inlet temperature does not exceed 55 C In Australia the use of a temperature control...

Страница 4: ...efully Symbol Meaning Material losses appliance damage consequential losses and environmen tal pollution Appliance disposal f f This symbol indicates that you have to do something The ac tion you need...

Страница 5: ...to the selected temperature This occurs regardless of the inlet temperature If the appliance is operated with preheated water and the inlet temperature exceeds the selected temperature the inlet temp...

Страница 6: ...perature flashes once to confirm 4 7 Inlet temperature information If the appliance is operated with preheated water and the inlet temperature exceeds the selected set temperature the inlet tem peratu...

Страница 7: ...sec 4 Circulation boost program Shower your arms and legs with cold water to boost circulation Spray from the hands and feet towards the body You can then repeat this process with hot water WW KW 3 m...

Страница 8: ...mote controls During unpairing rc0 appears on the display of the programming unit for 5 seconds then rc again 4 9 3 Deactivating the parameter menu f f Exit the menu item by pressing i and holding for...

Страница 9: ...and repair of the appliance 7 1 General safety instructions We guarantee trouble free function and operational reliability only if original accessories and spare parts intended for the appliance are...

Страница 10: ...n D0000056242 1 2 1 Cold water inlet 2 DHW outlet Oversink installation D0000057030 1 2 1 Cold water inlet 2 DHW outlet Note f f Mount the appliance on the wall The wall must have sufficient load bear...

Страница 11: ...r back panel section forwards Preparing the power cable on unfinished walls for connection from below 160 30 D0000053273 1 1 Cable entry installation aid f f Prepare the power cable Fitting the wall m...

Страница 12: ...outlet pipe from the pipework with flat gaskets to the extensions from the appliance Making the electrical connection WARNING Electrocution Carry out all electrical connection and installation work in...

Страница 13: ...over should be turned the other way up for easier operation see chapter Installation alternatives Rotated appliance cover Fit the appliance cover D0000040777 1 2 3 4 1 Pipe knock out 2 Cover guides 3...

Страница 14: ...ed from below short power cable IP 25 Finished walls IP 24 Water connection IP rating Unfinished walls IP 25 Other IP rating Installation with offset tiles IP 25 Rotated appliance cover IP 25 Horizont...

Страница 15: ...ns Deburr any sharp edges with a file f f Route the power cable through the cable grommet f f Connect the power cable to the mains terminal 13 4 Water installation on unfinished walls 12 D0000053319 f...

Страница 16: ...ersink installation D0000073012 f f Remove the programming unit from the appliance cover by pressing the locking hooks and removing the programming unit f f Turn the appliance cover not the appliance...

Страница 17: ...e appliance cover must be provided with a condensate drain opening of min 5 0 mm to max 6 0 mm at the marked po sition 50 5 0 D0000076914 1 2 1 Appliance cover with opening for condensate drain 2 Back...

Страница 18: ...atch set value Tap faulty Replace tap Outlet sensor faulty Replace outlet sensor Heating system faulty Replace the function module PCB faulty Replace the function module Green flashes yellow flashes r...

Страница 19: ...e can freeze and cause damage Clean strainer If the strainer in the threaded cold water fitting is dirty clean it Close the shut off valve in the cold water inlet line before remov ing cleaning and re...

Страница 20: ...l min Rated voltage Cold water inlet temperature 380 V 400 V 415 V 5 C 10 C 15 C 20 C DHE 18 AU 16 2 5 1 5 8 6 6 7 7 18 0 5 7 6 4 7 3 8 6 19 4 6 2 6 9 7 9 9 2 DHE 27 AU 23 5 7 5 8 4 9 6 11 2 26 0 8 3...

Страница 21: ...city l 0 4 0 4 Versions Adjustable connected load Temperature settings C Off 20 60 Off 20 60 Protection class 1 1 Insulating block Plastic Plastic Heating system heat generator Bare wire Bare wire Cov...