www.stiebel-eltron.com
SHW S |
23
EN
GL
ISH
INSTALLATION
Installation
Installation
f
f
Fit the cylinder casing.
f
f
Fit the cable grommet and control panel cover.
f
f
Push on the temperature selector.
f
f
If you use the "DHW circulation" connection to install a DHW
circulation line, you need to cut an opening in the cylinder
casing near the connection (indentation in the foam) for the
DHW circulation line.
f
f
Remove the thermal insulation near the connection.
f
f
Route the DHW circulation line through the aperture in the
cylinder casing and fit the DHW circulation line.
f
f
Insulate the "DHW circulation" connection.
f
f
Insert the supplied adaptor with flat gasket and an extension.
f
f
Cover the hole in the cylinder casing with the adhesive rose
supplied.
f
f
Fit the cover and the plinth trim of the cylinder casing.
10.2 Thermometer
26
�0
2�
09
�0
06
2
f
f
Insert the thermometer as far as it will go and align it.
10.3 Signal anode
!
Material damage
The appliance must not be operated without a consump-
tion indicator or with a damaged one, otherwise water
will leak out once the anode is depleted.
26
�0
2�
09
�0
06
3
1
2
1 Transport protection
2 Signal anode with consumption indicator
f
f
Remove the transport protection.
f
f
Check the consumption indicator for transport damage.
10.4 Water connection and safety assembly
10.4.1 Safety instructions
Note
Carry out all water connection and installation work in
accordance with regulations.
!
Material damage
When using plastic pipework, observe chapter "Specifi-
cation / Fault conditions".
!
Material damage
Operate the appliance only with pressure-tested taps.
Cold water line
Galvanised steel, stainless steel, copper and plastic are approved
materials.
A safety valve is required.
DHW line
Stainless steel, copper and plastic pipework are approved ma-
terials.