31
Assembly distance metal sheet
To completely replace the roof covering, there should be mounted intermediate plates. The intermediate plates have
therefore included a functional effect on the collector system and are necessarily.
For the collector types FKF 200 V, FKF 240 V and FKF 270 V, two distance metal sheets are mounted in every gap
between the collectors. For the collectors FKF 200 H, FKF 240 H and FKF 270 H, the assembly of one distance metal
sheet is planned. In case of multi-row systems, the distance metal sheets are mounted as described. The distance metal
sheets can be mounted from above or below.
Distance metal sheet
Distance metal sheets for the
assembly in one row
The distance metal sheet is inserted into the collector
grooves from above/below.
In case of vertical collectors or rather in case of multi-row
assembly of the collectors, further distance metal sheets
are inserted subsequently from above/below.
The distance metal sheet has to be inserted until it lines up
precisely with the lip (collector covering).
When assembling the distance metal sheets, please pay
attention to the waterflow
from the upper to the lower
distance metal sheet.
top
bottom
To avoid injury, it is recommended to use a piece of
wood to push the distance metal sheets into the collector
grooves.
The distance metal sheet will be sticked into the collector
groove to protect it against slipping out. The silicone strip
should have a length of 10 - 20 cm. Please note that the
distance metal sheet must be free of silicone residue to
ensure the flow of rainwater.
We recommend not to assemble the distance metal sheets
at a high insolation or temperature.
The potential thermal expansion of the collector may
cause difficulties when assembling.
For vertical panels, there is a upper and lower
intermediate plate.
1200531 Distance metal sheet FKF 200 V top
1200532 Distance metal sheet FKF 240 V top
1200533 Distance metal sheet FKF 270 V top
1200534 Distance metal sheet FKF
200 H / 240 H / 270 H top
1200535 Distance metal sheet FKF 200 V bottom
1200536 Distance metal sheet FKF 240 V bottom
1200537 Distance metal sheet FKF 270 V bottom
1200538 Distance metal sheet FKF
200 H / 240 H / 270 H bottom
Содержание FKF 200
Страница 1: ...Assembly instructions Solar collectors FKF 200 240 270 Roof integrated installation...
Страница 43: ...43 Initial operation Schematic drawing of the system construction and piping scheme...
Страница 44: ...44 Initial operation Schematic drawing of the system construction and piping scheme...
Страница 45: ...45 Notes Initial operation...
Страница 46: ...46 Notes Initial operation...