NOT TURN ON:
- The cables are not correctly connected (terminals BAT, GND and REM). Make sure that all connections
has mechanical and electrical contact.
- Fuses/circuit breakers (external) are defective or burned. Take care about the correct value of the
new fuse!
NO SOUND:
- The cables of speakers or plugs RCA are not connected correctly.
- Check if the LEVEL control is not in the minimum.
NO SOUND / RED LED (PROTECTION) ILLUMINATED:
- Speakers or cables (damaged), so, check speakers, cables and connections.
- Check the battery charge.
BAD SOUND QUALITY (DISTORTION):
- The speakers are overloaded, so, decrease the level and redo the gain adjustment (see iten 2/general
description).
WEAK BASS:
- Cables of speakers (+) and (-) are changed, speakers out of phase (see iten 5/general description).
HOW TO ACT IN CASE OF PROBLEMS
SPECIFICATIONS
VENOM LINE
VENOM LINE
USER’S GUIDE
MODEL:
V 1000.5 - STEREO
V 1000.5 - MONO
Channels:
4
1
Power @ 13.8V 2 Ohms:
4x100 Watts RMS
1x625 Watts RMS
Power @ 13.8V 4 Ohms:
2x200 BRIDGE Watts RMS
1x450 Watts RMS
Minimum Output Impedance
2 Ohms
2 Ohms
Input Impedance:
15K Ohms
Minimum Sensitivity:
0,2V
Total Harmonic Distortion:
< 0,9 % THD
Signal to Noise:
> 90 dB
Crossover HIGH PASS:
70Hz to 700Hz
Crossover LOW PASS:
-
50Hz to 20KHz
Freq. Response (-3dB) @ 2 Ohms:
20 Hz to 22 KHz
20Hz to 20KHz
Power Tension:
9 to 15V
Consumption Signal Musical:
1,5 to 45A
Consumption Signal BASS:
1,5 to 90A
Dimensions (A x L x C):
40x240x365 mm
Weight: