23
Setting dipswitches DS2
Switch 1 2 3 4 Time(s)
1
0 0 0 0 0,5
2
1 0 0
0 0,6
3
0 1 0 0 0,7
4
1 1 0 0 0,8
5
0 0 1 0 0,9
6
1 0 1 0 1,0
7
0 1 1 0 1,1
8
1 1 1 0 1,2
*)
9
0 0 0 1 1,3
10
1 0 0 1 1,4
11
0 1 0 1 1,5
12
1 1 0 1 1,6
13
0 0 1 1 1,7
14
1 0 1 1 1,8
15
0 1 1 1 1,9
16
1 1 1 1 2,0
0 = OFF 1 = ON
*)
Standard setting
FAILURE COMBILOK DURING LOCKING
A.
Stops during longitudinal movement.
Press button "reset alarm" once to silence alarm. Press
"release truck" button once to bring Combilok in starting
position. Press "block truck" button once to lock. With
repeated failure call in service department.
B.
Stops at the end of the longitudinal
movement.
No wheel signalized during locking movement. If required,
clean the lens of the sensor with a soft cloth. The range of
the wheelsensor is possibly not adjusted correctly. Check
and eventually adjust as described in paragraph 4.3.1.
Furthermore same procedure as A.
C.
Transverse movement started but not
completed.
Transverse guide jammed due to obstacle. Check clearance
behind wheel. Furthermore same procedure as A.
NO CONTROL VOLTAGE (see control panel fig. 2A)
No LEDS light on the front.
A.
Control voltage (not yet) switched on.
Press 'reset alarm' 1 x.
B.
Emergency-push button pressed in.
Unlock in the direction of the arrow and press reset alarm
button 1 x.
C.
Keyboard not functioning.
Check internal plug connection.
D.
Automatic fuse activated.
Reset fuse by switching off and on the main switch.
Alert service department if problem returns.
E.
Fuse defective.
Replace fuse F1 (630 mAT), see FIG. D.
NO MAINS VOLTAGE (see control panel fig. 2A)
No LED lights on the front.
A.
Mains voltage not present.
Have fault repaired by recognized electrician.
B.
Mains fuse defective.
Replace the defective fuse.
C.
Main switch off.
Turn on main switch.
EXTERNAL LIGHT INDICATION NOT FUNCTIONING
A.
Fuse defective.
Replace fuse F1 (630 mAT), see FIG. D.
B
Neutral conductor not connected.
Fit neutral conductor.
5.3
POWER FAILURE
In the event of a power failure the locking system can be made pressureless
manually. The handle of the hand tap (pos. 8 in FIG. J) under the cover of the
hydraulic unit is placed in line with the connections. The extendible unit can be
retracted using a suited tool (long gluing clamp) for this purpose.
5.4
REACTION TIME TRANSVERSE MOVEMENT
Ex works the Combilok is set so that the transverse movement starts if nothing
is detected within 1,2 seconds after wheel detection. If in specific cases it turns
out to be necessary having to choose another setting, is this possible by means
of dipswitches DS2, see FIG. D and adjacent table.