6
Operating instructions (Version 0)
43
ST 1075
6
Inspection and maintenance
6.1
General
Always completely lower the column lifts and switch off the mains power switch
(position 0) during inspection and maintenance.
The power may be only temporarily switched on, and the lift placed in a higher
position, when required for performing certain checks and adjustments.
Warning
w
When the column lifts are in a raised position, always lower them into the safety lock.
Once a year, the column lifts must be subjected to a thorough check by a technical
service recognized by Stertil B.V.; see section
6.2
Maintenance schedule
6.2.1 Daily checks by the user
1.
Inspect the column lifts for visible damage.
2.
Check whether there has been any oil leakage from the hydraulic unit, the hoses or
the cylinder.
3.
Check the battery capacity.
6.2.2 Monthly maintenance by the user
1.
Check the operation of the safety locking feature as described in §
the safety locking feature" on page 47
.
Note
n
If this does not function correctly, consult the technical service.
2.
Check the emergency shutdown mechanism as described in §
emergency shutdown mechanism" on page 47
.
3.
Carry out the monthly lubrication programme as set out in
.
Содержание ST1075-FBF
Страница 21: ...Safety Operating instructions Version 0 21 ST 1075 2 Figure 2 2 Safety and warning labels ...
Страница 78: ...Operating instructions Version 0 78 ST 1075 A 2 Hydraulic unit Figure A 2 Hydraulic unit ...
Страница 85: ...List of parts and appendices Operating instructions Version 0 85 ST 1075 A Figure A 5 3 Control box ...
Страница 90: ...Operating instructions Version 0 90 ST 1075 A 9 Label locations Figure A 9 Label locations ...
Страница 100: ...Operating instructions Version 0 100 ST 1075 Date Remarks Name of mechanic Initials of mechanic pass ...