![stertil-KONI ST 1082-FS Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/stertil-koni/st-1082-fs/st-1082-fs_installation-operation-and-maintanance-instructions_1375431041.webp)
Operation
Operating instructions (Version F)
41
ST 1082 & ST 1100
5
5.5.2 System functions
Figure 5.1 "Control boxes" on page 35
available by pressing:
<UP> (button 3)
all columns rise.
<DOWN> (button 4)
Lowering in the safety locks
<UNLOCK> (button 6) and <UP> (button 4)
all column lifts lower.
<SELECT> (button 5) and <PAIR> (light 11) and <UP> (button 3)
one axle rises (2 column lifts).
<SELECT> (button 5) and <PAIR> (light 11) and <DOWN> (button 4)
one axle lowers (2 column lifts).
<SELECT> (button 5) and <SINGLE> (light 10) and <UP> (button 3)
one column lift rises.
<SELECT> (button 5) and <SINGLE> (light 10) and <DOWN> (button 4)
one column lift lowers.
<TORTOISE> (icon) and <DOWN> (button 4)
columns lower slowly.
This works for <ALL>, <PAIR> and <SINGLE>.
Note
n
Lower the column lifts in the safety locks and set the mains switch to 0 (OFF) once
the desired height has been reached.
When using just one or two column lifts (when operating in pairs), make certain that
there is no possible danger of instability; see also section
). If in doubt, ask your supervisor.
Warning
w
Unsafe hoisting can lead to serious injuries and damage to the lifting system and the
vehicles.
5.5.3 Unblocking in case of emergency
In emergency situations, it is possible to lower the column lifts manually. Manual
lowering may only be carried out by an authorized technician.