Operating instructions (Version F)
22
ST 1082 & ST 1100
3.2
Lifting capacity
for specifications of the maximum lifting capacity. The
overpressure safeguard in the hydraulic unit has been preset so that the lift can
never raise more than the specified 10%.
The design is calculated for a maximum load of 18,000 lbs on any one column.
Lifting column
interconnection cable length
39' - 4"
39' - 4"
Maximum distance between
two column lifts
approx. 29' - 6"
approx. 29' - 6"
Maximum floor surface
pressure
900 psi (per front
support) ST 1082-RS
7000 psi (per wheel)
ST 1082-FS
900 psi (per front
support) ST 1100-RS
7000 psi (per wheel)
ST 1100-FS
Maximum floor loading
7000 lbs (per front
support)
7000 lbs (per front
support)
Operating temperature
-15 to +50
0
C / 5 to 122
0
F -15 to +50
0
C / 5 to 122
0
F
Table 3.1
Specifications
Model
ST 1082-FS/RS
ST 1100-FS/RS