Service and Parts manual (Version B)
76
Wireless
6.6.4
The column lift is not raised far enough
Cause
Solution
Oil level in the tank is too low.
Top up with oil as described in Hydraulic
oil.
Pump is drawing air.
Tighten or crimp the suction filter
attachment.
The steel plug has not been replaced by
the air bleed cap.
Fit the air bleed cap.
The air bleed cap is blocked.
Clean the air bleed cap.
6.6.5
No battery power
Cause
Solution
No battery power.
Charge the batteries using the mains
cable supplied.
DO NOT USE AN
EXTERNAL BOOSTER CHARGER.
Have the batteries checked by a battery
specialist.
The main fuse has blown.
Check the main fuse above the batteries.
The main switch is
OFF
.
Set the main switch to
ON
.
Indicator lights and/or screen defective.
Contact technical services
6.6.6
No control voltage
Cause
Solution
Indicator lights and/or screen defective.
Lifting system functioning normally.
Contact technical services.
The lifting system may not be set up
properly.
Follow the normal operation procedures
as described in the Operation Manual. If
the fault occurs again, contact technical
services.
A fuse has cut power to the controller.
The controller has multi-fuse circuit
breakers. After they have cooled down,
they switch back on again automatically.
If the fault occurs again, contact technical
services.
The main switch is
OFF
.
Set the main switch to
ON
.
Содержание ST 1065-FWF
Страница 1: ...Mobile column lifts Wireless Service and Parts manual 2015 Stertil B V 38007815 B ...
Страница 109: ...Service and Parts manual Version B 109 Wireless 8 18 Hydraulic cylinder ST1075 ...
Страница 111: ...Service and Parts manual Version B 111 Wireless 8 19 Hydraulic cylinder ST1065 ST1085 ST1100 ...
Страница 123: ...Service and Parts manual Version B 123 Wireless 10 APPENDICES 10 1 Electrical connections fig 37 Electrical connections ...