background image

WARNING

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

CAUTION

CLEANING & MAINTENANCE

OPERATION

For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the dusting brush attachment.

The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the 

exact service motor. The impeller should also be replaced.

See “Connect Wiring” for details.

EXHAUST FAN

SED110

SED110M

a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer

b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switching 

on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 

c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated 

construction codes and standards. 

d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. 

Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), 

and the American Society for Heating, Refrigeration and Air Conditioning   Engineers (ASHRAE), and the local code authorities. 

e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 

f). Ducted fans must always be vented to the outdoors. 

g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit (ceiling installation only). 

h). This unit must be grounded. 

i). Not for Use in Kitchens.

j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within walls or ceilings or into attics, 

crawl spaces, or garages

k).  WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.

l). The fan must not be installed in a ceiling thermally insulated to a value greater R40.

1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 

2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT THIS 

PRODUCT IN A WALL. 

3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 

4. Please read specification label on product for further information and requirements. 

   *The manual in electronic format can be download in our company web, or obtained from our dealer.

WARNING -TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE 

FOLLOWING:

-

+

-

+

1 2 3

1 2 3

Toggle switch

Power box

Low airflow 

knob

Timer delay

 knob

80 90 110 120 90 110 120 140

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

6"

Switch 

position

Duct 

diameter

(inches)

Airflow

(CFM)

6"

6"

6"

4"

4"

4"

4"

80 90 110 120 90 110 120 140

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

1 2 3

6"

Switch 

position

Duct 

diameter

(inches)

Air deliver

(CFM)

6"

6"

6"

4"

4"

4"

4"

is the position of switch

Other airflow reference performance based on HVI 

Procedures 915, 916, and 920.

Factory setting: 110CFM (                    ) 

HVI Certified performance based on HVI Procedures 915,

916, and 920.

The control box, located inside the fan housing, has three separate adjustments: 

(1) The low airflow knob adjusts the lower airflow from 30CFM up to 

the air flow rate of the high fan speed determined by the toggle switch setting.  

(2) The time delay knob is adjustable from 3 to 30 minutes and will switch the fan 

to the low speed setting after motion is no longer detected in the room for the set 

period of time. 

(3) The toggle switch will adjust the upper fan speed setting from 80 to 120 CFM 

using a 4" duct, or 90 to 140 CFM using a 6" duct.  

with 6" duct

How to work

To Turn Fan ON

Turn the switch 

I

 (according to the following “CONNECT ELECTRICAL WIRING” ) ON.

• Fan will run at the certified airflow rate if the switch 

II

 is ON.

• Fan will run at the user-adjustable airflow rate if the switch 

II

 is OFF.

To Use Fan Time Delay Airflow Rate Change

1. Turn the switch 

I

 ON.

2. Turn the switch 

II

 ON - fan will run at the certified airflow rate.

3. When the switch 

II

 is turned OFF, fan will continue to run at 

the certified airflow rate until the user-adjustable time delay has elapsed, 

and then will automatically change to the user-adjustable airflow rate.

To Turn Fan OFF

Turn the switch 

I

 OFF

For  model SED110

Содержание SED110M

Страница 1: ...lled in a ceiling thermally insulated to a value greater R40 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in ceilings up to a 12 12 pitch 45 degree angle Duct connector must point up DO NOT MOUNT THIS PRODUCT IN A WALL 3 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywal...

Страница 2: ...a cooking area 2 Two ways to connect ductwork to a factory shipped unit ASSEMBLY INSTRUCTIONS 1 Housing mounted to I joists Start at ASSEMBLY INSTRUCTIONS 1 2 Housing mounted to joists Start at ASSEMBLY INSTRUCTIONS 1 3 Housing mounted to truss Start at step ASSEMBLY INSTRUCTIONS 2 SCREW 2 ROOF CAP with built in damper ROUND DUCT WALL CAP with built in damper Purchase separately POWER CABLE INSULA...

Страница 3: ... plate Refer to the wiring diagram and connect the wires as shown FAN FAN LIGHT SWITCH BOX BLK WHT D Low CFM switch S elay time Preset switch Fan N LED Sensor and LED Light GRD UNIT SWITCH SWITCH BLK WHT LINE IN LED NIGHT CONTROL CIRCUIT BRN UNIT BLACK BLK LED NIGHT LIGHT SWITCH BOX FAN 120V AC LINE IN GROUND GRD BROWN BRN WHITE WHT WIRE PANEL RECEPTACLE For model SED110 For model SED110M UNIT BLA...

Страница 4: ...he remedy provided in this warranty is exclusive and is granted in lieu of all other remedies This warranty does not cover incidental or consequential damages Some states do not allow the exclusion of incidental or consequential damages so this limitation may not apply to you Some states do not allow limitations on how long an implied warranty lasts so this limitation may not apply to you This war...

Отзывы: