![Steris Basil 4700 Скачать руководство пользователя страница 117](http://html.mh-extra.com/html/steris/basil-4700/basil-4700_maintenance-manual_1374318117.webp)
3-6
764333-098
3.14.4 Alkaline Wash Tank Heating Alarm
If after 10 minutes (default value adjustable in service
mode only), alkaline wash tank water temperature is
not reached, control gives an alarm.
3.15 ACID WASH TANK MONITOR
3.15.1 Acid Wash Tank Filling
If acid tank high water level switch (1 in 10) indicates
that acid wash tank is not full, control energizes acid
tank fill valve (5 out 4) for 5 minutes (default value
adjustable in service mode only) or until acid wash
tank is full. Once acid tank high water level switch
detects water (1 in 10) for 3 consecutive seconds, con-
trol de-energizes acid tank fill valve (5 out 4).
3.15.2 Acid Wash Tank Filling Alarm
If after 5 minutes (default value adjustable in service
mode only), acid tank high water level switch does not
detect water (1 in 10), control gives an alarm.
3.15.3 Acid Wash Tank Heating
Once acid wash tank is full, control energizes acid tank
steam valve (5 out 6) to start heating acid wash tank
water up to 140.0
°
F [60.0
°
C] (default value adjustable
in service mode only) for 10 minutes (default value
adjustable in service mode only). Once temperature set
point is reached, control de-energizes acid tank steam
valve (5 out 6).
3.15.4 Acid Wash Tank Heating Alarm
If after 10 minutes (default value adjustable in service
mode only), acid wash tank water temperature is not
reached, control gives an alarm.
3.16 MISCELLANEOUS NOTES
3.16.1 Bypass Button
A BYPASS button is present on Cycle Status display.
A cycle phase may be bypassed only if Temperature
Guaranteed is not selected. Recirculation, soaking and
exhaust phases can be bypassed. A message is printed
when a phase is bypassed.
3.16.2 Extend Button
An EXTEND button is present on Cycle Status display.
Pressing EXTEND button adds time to remaining
phase time. E.g. if 1 minute remains from a 5 minute
recirculation and the EXTEND button is pressed, the
recirculation timer is extended to 6 minutes.
Recirculation, soaking and exhaust phases can be
extended. A message is printed when a phase is
extended.
3.17 MANUAL MODE DESCRIPTION
User or service technician can manually control certain
washer functions by accessing Manual Control mode.
Manual Control mode is accessible from Operating
mode when washer is not in cycle. By pressing
MAN-
UAL MENU
button, the following sequences are avail-
able in this mode:
3.17.1 Fill
By selecting FILL, filling port valve is activated and
sump fills. Display shows FILLING SUMP. Once sump
level reached, display shows SUMP FULL. If a door is
opened or FILL button is pressed again, sequence is
aborted. Filling valve closes automatically when sump
is full.
3.17.2 Pump/DRV
By selecting PUMP/DRV the following sequence
occurs: sump is filled; then, recirculation pump, jet
valve and header system are activated. Display shows
PUMPING/DRIVING.
If a door is opened or PUMP/DRV button is pressed
again, the sequence is aborted.
3.17.3 Drive
By selecting DRIVE header system is activated. Dis-
play shows DRIVING. If DRIVE button is pressed
again, sequence is aborted.
3.17.4 Drain
By selecting Drain, you can drain the following:
Sump
Acid Tank (appears only if option selected)
Alkaline Tank (appears only if option selected)
Cooldown (appears only if option selected)
• Sump
Sump is filled to ensure pump does not run
dry. Recirculation pump is activated and drain
valve opens. Display shows DRAINING
SUMP.
Once drain time has elapsed, display shows
SUMP EMPTY. If a door is opened or SUMP
button is pressed again, sequence is aborted.
If cooldown tank is present, this one is drained
using manual cooldown tank draining
sequence.
Содержание Basil 4700
Страница 1: ...MAINTENANCE MANUAL Basil 4700 Cage and Rack Washer 2008 10 15 P764333 097 ...
Страница 3: ...OPERATOR MANUAL Basil 4700 Cage and Rack Washer 2008 08 14 P920509 645 ...
Страница 87: ...MAINTENANCE MANUAL Maintenance Instructions Basil 4700 Cage and Rack Washer 2008 10 15 P764333 098 ...
Страница 169: ...MAINTENANCE MANUAL IIlustrated Parts Breakdown Basil 4700 Cage and Rack Washer 2008 10 15 P764333 099 ...
Страница 172: ...2 764333 099 Figure 1 Basil 4700 Cage and Rack Washer Inside Washer Inside Inside Washer ...
Страница 174: ...4 764333 099 Figure 2 Cabinet Assembly Left Side Control Shown ...
Страница 176: ...6 764333 099 Figure 3 Sump and Floor Grating Assembly ...
Страница 178: ...8 764333 099 Figure 4 Door Assembly ...
Страница 180: ...10 764333 099 Figure 5 Double Door Interlock System ...
Страница 182: ...12 764333 099 Figure 6 Interior Light ...
Страница 184: ...14 764333 099 Figure 7 Safety Emergency Stop Cable Assembly ...
Страница 186: ...16 764333 099 Figure 8 Spray Header Assembly ...
Страница 188: ...18 764333 099 Figure 9 Cable and Roller Assembly DETAIL A DETAIL B See Detail A See Detail B ...
Страница 190: ...20 764333 099 Figure 10 Traveler Drive and Limit Switch Assembly See Detail A DETAIL B DETAIL A See Detail B ...
Страница 192: ...22 764333 099 Figure 11 Automatic Water Rack Flush System For Two Racks Option ...
Страница 194: ...24 764333 099 Figure 12 Damper 1 ...
Страница 196: ...26 764333 099 Figure 13 Exhaust Fan ...
Страница 198: ...28 764333 099 Figure 14 Hot Water Line Components 6 5 4 10 10 7 8 9 7 ...
Страница 200: ...30 764333 099 Figure 15 Cold Water Line Components ...
Страница 202: ...32 764333 099 Figure 16 Recirculation Piping ...
Страница 204: ...34 764333 099 Figure 17 Steam Line Components ...
Страница 206: ...36 764333 099 Figure 18 Final Rinse System Assembly ...
Страница 208: ...38 764333 099 Figure 19 Recirculation Pump System and Self Cleaning Filter UC DRAIN TANK 1 TANK 2 SPRAY HEADER ...
Страница 210: ...40 764333 099 Figure 20 Pneumatic Block ...
Страница 212: ...42 764333 099 Figure 21 Peristaltic Chemical Injection Pumps ...
Страница 214: ...44 764333 099 Figure 22 Solution Tank 25 ...
Страница 216: ...46 764333 099 Figure 23 Tank Support Frame ...
Страница 218: ...48 764333 099 Figure 24 Guaranteed Cooldown Tank ...
Страница 220: ...50 764333 099 Figure 25a Electrical Box and Control Column Assembly ...
Страница 226: ...56 764333 099 Figure 26 Control Panel See Detail A DETAIL A ...
Страница 228: ...58 764333 099 Figure 27 Seismic Tie Down Anchorage Option ...
Страница 230: ...60 764333 099 Figure 28 Bottle Washing Cart WA02 010 ...
Страница 232: ...62 764333 099 Figure 29 Bottle Washing Cart WA02 020 ...
Страница 234: ...64 764333 099 Figure 30 Pan Cart WA02 030 Accessory ...
Страница 236: ...66 764333 099 Figure 31 Universal Cage and Pan Wash Cart WA03 100 7 ...
Страница 238: ...68 764333 099 Figure 32 Universal Cage Wash Cart WA02 040 ...
Страница 240: ...70 764333 099 Figure 33 Cart Tilt Ramp WA02 050 ...
Страница 242: ...72 764333 099 Figure 34 Floor Ramp for Floor Mounted Units WA02 060 ...
Страница 244: ......
Страница 245: ......
Страница 246: ......
Страница 247: ......
Страница 248: ......
Страница 249: ......
Страница 250: ......
Страница 251: ......
Страница 252: ......
Страница 253: ......
Страница 254: ......
Страница 255: ......
Страница 256: ......
Страница 257: ......
Страница 258: ......
Страница 259: ......
Страница 260: ......
Страница 261: ......
Страница 262: ......
Страница 263: ......
Страница 264: ......
Страница 265: ......