CAUTION 1:
TURN ALL POWER OFF. NEVER EXPOSE EYES OR SKIN TO UVC LIGHT FROM ANY SOURCE - WEAR GLOVES,
FACE SHIELD AND COVER ALL EXPOSED SKIN. DO NOT TOUCH EMITTER
TM
GLASS WITHOUT GLOVES.
CAUTION 2:
INSTALL EMITTER TUBE BEFORE APPLYING POWER. FAILURE TO DO SO WILL TRIGGER THE "END-OF-LAMP-
LIFE CIRCUIT" AND THE EMITTER WILL FAIL TO LIGHT! IF THIS HAPPENS SHUT OFF POWER FOR 10 SECONDS, REINSTALL /
INSTALL EMITTER AND TURN POWER BACK ON. EMITTER WILL LIGHT.
NOTE: Read this entire instruction sheet before starting the installation.
Made in USA
p
WARNING
!
Before installing fixture or performing maintenance or service on
fixture, turn off main power switch to unit. Electrical shock can cause
injury or death. There may be more than one disconnect switch.
p
CAUTION
!
Never expose eyes or skin to ultraviolet light from any source. After
installation, provide an interlock to turn off germicidal lamps when
access door is opened. Lamp must be off before entering HVAC unit
to perform maintenance or service. Personal injury may result.
p
CAUTION
!
Do not touch lamp glass without gloves. Damage to Emitter™ may
result. Oil from fingerprints will permanently etch glass of lamp and
weaken structure. Clean lamp after handling.
p
CAUTION
!
Use only specified high-output, low temperature lamp with this
fixture. Use of a lower wattage or incorrect lamp can result in
damage to accessory or Emitter.
Safety Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.0
Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.0
Operation & Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.0
Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.0
Illustrations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.0
Spare or Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.0
1.0 SAFETY CONSIDERATIONS
TABLE OF CONTENTS
MODEL
SE SERIES
120-277 Vac.
Patents 5,334,347; 5,817,276; 5,866,076; 6,245,293; 6,267,924;
6,280,686; 6,313,470; 6,372,186; 6,423,882; 6,500,267; 6,589,476; 6,627,000
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Improper installation, adjustment, alteration, service,
maintenance, or use can cause fire, electrical shock, or
other conditions which may cause personal injury or
property damage.
Consult a qualified installer, service
agency, or your supplier for information or assistance.
The qualified installer or agency must use factory kits or
accessories when installing this product.
Refer to the
individual instructions packaged with kits or accessories
when installing them.
Follow all safety codes, wear safety glasses and work
gloves. Read all instructions thoroughly and follow any
warnings or cautions attached to any accessed area.
Consult local building codes and the National Electrical
Code (NEC) for special requirements.
Understand the signal words
DANGER, WARNING
or
CAUTION.
These words are universally used for overall
safety.
DANGER
identifies the most serious hazards,
which will result in severe personal injury or death.
WARNING
signifies hazards, which could result in
personal injury or death.
CAUTION
is used to identify
unsafe practices, which would result in minor personal
injury or product and property damage.
p
CAUTION
!
Lamp contains a small quantity of mercury. If an lamp breaks, clean
and dispose of with care.