Stella iR4-LGDW Скачать руководство пользователя страница 1

W W W . S T E L L A D O R A D U S . C O M

W W W . S T E L L A D O R A D U S . C O M

i

REPEATER

i

REPEATER

1

1

Contents of the kit

Dimensional Drawing(mm)

Snap QR code to visit 

Installer Zone for more 

installer resources.

This manual is for the following models

Blue box - band is active

The LCD allows users to easily read the repeater diagnostics, control the gain of each band, turn on/off any band, and 

easily allows for general configuration.

*The iR4 has only 2 ports for 2 internal antennas.

dB Page

Main Page

LCD - 5” full colour touch

Quick installation and user manual

Long press to reboot:This is similiar to plugging out and in mains power.
Short press to reset:  This just rebalances the levels.

Band is Active.

Frequency

No issues
Band is self optimizing.
Strong outdoor signal. No action required as the repeater will self optimize.
Indoor and outdoor antennas are too close to each other. Separate them more.
External signal is too strong and band has shut down. Add manual attenuation.
Band has automaticlly turned off due to very high downlink (DL) power.

Internet status

2-After using group attenuators, use these individaul attenuators to do fine adjustments per band.

Uplink (UL) power received by the amplifier. (Power emitted by the phone)

DL power from the operator, received by the amplifier.

UL Automatic Gain Control (AGC) - starts when  UL power limit is reached

AGC for UL and DL when the operator’s signal is strong.

When outdoor signal is very strong, gain is reduced for an extended time.

Add extra attenuation to high or low bands.

Add attenuation to any band individually.

Sum of total  AGC on the DL. This value can be  used  in FloorPlanner tool.

Yellow box - strong uplink from phone.

Outdooor

 antenna

*Outdoor 15m

cable SD400

*Indoor

antennas x 4

Indoor cables

4x SD400

*Custom cable lengths supplied

iRepeater

                   PIN Access

A secret PIN can lock out access to the LCD display. The PIN is set on the clients account on the platform. Default 
PIN 888888,

                   Internal location

Enter a note about the amplifier. This note is sent and displayed on the stellacontrol inventory page.  E.g. Internal 
location of the amplifier.

Other LCD features

Toggle Band Page

Model

Bands

                                    

Ports

     

PSU

Weight

Dims cm

iR4-LGDW*

B20,B8,B3,B1

2

12V,5A

1.6kg

27X29X3.8

iR5-EU

B20, B8, B3, B1, B7                                                

4

12V,5A

2.8kg

43X30X3.8

iR6-EU

B28, B20, B8, B3, B1, B7        

4

12V,5A

2.8kg

43X30X4.8

iR5-US

B28, B4, B5, B25, B7

4

12V,5A

2.8kg

43X30X4.8

1-Use high and low group attenuator to control either the low bands 700/800/900 
and/or the high bands, 1800/2100/2600.
Use these group attenuators to first control very strong signal. Then, make fine 

adjustments with the individual attenuators.

Switch On/Off band 