FUNCTIONING ( 2T-4T NO ALLUMINIUM )
START
SPEED
AND
START
TIME
FUNCTIONING ( 2T ALLUMINIUM )
HOT
START
AND
BASE
CURRENT
FUNCTIONING
( 4T ALLUMINIUM )
DOUBLE PULSE
In the pulsed synergic programs it is possible to
activate the DOUBLE PULSE.
Double pulse activation standard.
Press the DP MODE button (ref.9) access the MIG
DOUBLE PULSE PARAMS screen. To activate the
standard double pulse (parameters that can not be
modified) press the DP ON (ref.9). The parameters
are highlighted in blue.
Double manual pulse activation.
To activate the manual double pulse (modifiable
parameters) press the DP ON button (ref.9) and
then the MAN button (ref.10). It is possible to
modify the three parameters of the double pulse
highlighted with the black color.
-DP
Frequency
(double
pulse
frequency)
adjustable from 0.5 to 4 Hz.
-DP DutyCycle (Duty cycle) adjustable from 20 to
80%.
-DP Mot.Perc. (Percentage compared to the main
parameter) adjustable from 40 to 90%.
To deactivate the Manual or Standard Double
Pulse press the DP MODE button (ref.9) and then
the DP OFF button (ref.9).
PROTECTION FOR
OVERCURRENT
If the welding current is more than 580 Ampere
there is a protection that automatically reduces the
wire speed and the welding parameters.
In the event the wire speed will show in the follow
mode :
-
Lower welding parameters.
-
The wire speed symbol change color.
-
The value of wire speed flashing changing
color.
The operator must set again the wire speed with a
lower parameter compare to the original parameter
that sent in protection the machine.
PAW™
(PRECISION ALUMINIUM WELDING)
New welding process studied by Stel specially for
welding of thin aluminum sheets from 0,8mm to
2mm thick.