US Quattro COM1-24
US Quattro COM2-24
US Quattro DIM-24
DT Quattro COM1-24
DT Quattro COM2-24
DT Quattro DIM-24
US Quattro
US Oneway
DT Quattro
US Hallway
US Oneway COM1-24
US Oneway COM2-24
US Oneway DIM-24
US Hallway COM1-24
US Hallway COM2-24
US Hallway DIM-24
Information
FR
EN
Страница 1: ...Quattro DIM 24 DT Quattro COM1 24 DT Quattro COM2 24 DT Quattro DIM 24 US Quattro US Oneway DT Quattro US Hallway US Oneway COM1 24 US Oneway COM2 24 US Oneway DIM 24 US Hallway COM1 24 US Hallway COM...
Страница 2: ...e Sensor module Mounts to a 4 Square box 4 Octagon box or Round 3 0 Mud Ring 120 US Quattro DT Quattro US Oneway US Hallway 120 a Mounts directly to ceiling with quick mount spring tabs 120 120 120 41...
Страница 3: ...o COM2 24 US Oneway COM2 24 US Hallway COM2 24 Light level setting See page 18 Occupancy time delay setting See page 18 HVAC stay ON time See page 19 HVAC switch ON delay See page 19 e f g d d c h k k...
Страница 4: ...24 DT Quattro DIM 24 US Oneway DIM 24 US Hallway DIM 24 e f m d d k k c Light level setting See page 18 Occupancy time delay setting See page 18 Stay ON time DIM before OFF See page 19 Reach setting S...
Страница 5: ...5 US Quattro COM1 24 DT Quattro COM1 24 US Oneway COM1 24 US Hallway COM1 24 Light level setting See page 18 Occupancy time delay setting See page 18 Reach setting See page 19 20 e f i d d c k k EN...
Страница 6: ...tay ON time Switching output 2 h HVAC switch ON delay Switching output 2 i Reach setting 10 1 COM1 24 Wiring 10 2 COM2 24 Wiring 10 3 COM2 24 Multiple Sensor Wiring 10 4 DIM 24 Wiring 10 5 DIM 24 Mult...
Страница 7: ...g Occupancy time delay Pulse mode IQ mode US Quattro COM2 24 DT Quattro COM2 24 US Oneway COM2 24 US Hallway COM2 24 1 low voltage switching output operating in relation to the detection of motion and...
Страница 8: ...2 3 4 5 6 7 8 9 10 11 12 13 14 ft 45 5 42 5 39 36 32 5 29 5 26 23 19 5 16 5 13 10 6 5 3 3 0 3 3 6 5 10 13 16 5 19 5 23 26 29 5 32 5 36 39 42 5 45 5 Coverage diagram at 9 ft mounting height One grid li...
Страница 9: ...Detector Control Pro COM1 24 Slave Presence Detector Power Pack Power Pack Neutral Hot Neutral Hot White Neutral Black Hot Red Relay Red Load Blue Control Black 24 VDC Red 24 VDC Green Switch Input Br...
Страница 10: ...rmally Open YELLOW WITH RED STRIPES 7 HVAC Relay Normally Common YELLOW 8 HVAC Relay Normally Closed YELLOW WITH BLACK STRIPES Neutral Hot White Neutral Black Hot Red Relay Red Load Load Optional Line...
Страница 11: ...ELLOW WITH BLACK STRIPES Optional LineVoltage Maintained Contact Switch Neutral Hot Blue Control Black 24VDC Red 24VDC Gray Momentary Switch Power Pack Control Pro COM2 24 Master Presence Detector Con...
Страница 12: ...ming ballast input VIOLET 7 10V dimming ballast input GRAY Note Power Pack must be in Auto mode Neutral Hot 0 10V Dimming Ballast Power Pack Optional LineVoltage Maintained Contact Switch Control Pro...
Страница 13: ...must be in Auto mode Neutral Hot Load Power Pack Optional LineVoltage Maintained Contact Switch Control Pro DIM 24 Master Presence Detector Control Pro DIM 24 Slave Presence Detector Blue Control Blac...
Страница 14: ...Normallyopen Yellow Red Normallyclosed Yellow Black 1A 30VAC VDC50 60Hz USQuattro DTQuattroDIM 24 USOneway USHallwayDIM 24 Controloutput Blue 1A 30VAC VDC50 60Hz 1 10voltdimmingoutput Purple Gray 100m...
Страница 15: ...T Quattro COM1 24 COM2 24 DIM 24 2 5 3 5 m 8 12 ft US Oneway US Hallway COM1 24 COM2 24 DIM 24 2 5 3 5 m 8 12 ft Environment IP 20 For indoor use only Sensor technology DT Quattro COM1 24 COM2 24 DIM...
Страница 16: ...as the room is occupied Once the room is no longer occupied and the time delay of the sensor has elapsed the sensor will return to the automatic ON function Manual ON mode MAN Automatic mode AUTO Auto...
Страница 17: ...occupancy Sensor technology used to turn the load on PIR US Both Either Maintain Occupancy Sensor technology used to keep the load on after initial occupancy PIR US Both Either The trigger mode is sel...
Страница 18: ...hed ON for approx 2 sec Afterwards the sensor does not respond to movement for approx 8 sec For use with a time delay relay Turned fully clockwise The stay ON time is self learning and adjusts dynamic...
Страница 19: ...iometer g Potentiometer h Potentiometer i Provides basic illumination for the selected stay ON time when am bient light falls below the selected brightness threshold that is set This can be dimmed to...
Страница 20: ...ON time is self learning and adjusts dynamically to user behaviour The optimum time is determined by means of a learning algorithm The shortest time is 2 min the longest time 20 min Test mode The tes...
Страница 21: ...ch as needed dur ing video or presentation viewing Controls only lighting and does not effect HVAC outputs of the COM2 24 The ON OFF function works with all of the Control Pro sensors Reset Returns se...
Страница 22: ...me if necessary L Readjust coverage zone or apply masking material L Increase stay ON time L Change light threshold L Reduce stay ON time L Adjust sensor s time delay or use with a time delay relay Ma...
Страница 23: ...10031888 09 2014 Technical changes subject to no prior noti cation STEINEL America Inc 9051 Lyndale Avenue South USA Bloomington MN 55420 Tel 1 800 852 4343 Fax 1 952 888 5132 www steinel net M 11127...