background image

- 12 -

- 13 -

GB

1.  About this document

 

–  Please read carefully and keep in a 

safe place.

 

–  Under  copyright. 

Reproduction either in whole or in part 

only with our consent. 

 

–  Subject to change in the interest of 

technical progress.

Symbols

!

Hazard warning!

 

...

 

Reference to other information 

in the document.

2.  General safety precautions

 Disconnect the power supply 

before attempting any work  

on the sensor.

•  During installation, the electric power 

cable being connected must not be 

live. Therefore, switch off the power 

first and use a voltage tester to make 

sure the wiring is off-circuit.

•  Installing the sensor involves work  

on the mains power supply. This  

work must therefore be carried out 

professionally in accordance with  

national wiring regulations and electri-

cal operating conditions.

•  Only use genuine replacement parts

•  Repairs may only be made by spe- 

cialist workshops.

 

3.   HF 360-2 KNX  / 

 

Hallway KNX

Proper use

 

– Sensor for ceiling mounting indoors.

 

– Connection to the KNX bus system.

The HF 360-2 KNX sensor also detects 

movements through thin walls. This 

makes it ideal for WC facilities with toilet 

cubicles, changing rooms, stairwells, 

multi-storey car parks and kitchens.

The detection zone of the sensor can be 

precisely limited by ETS.

The Hallway KNX Sensor is a high- 

frequency sensor with a perfect detection 

zone for corridors. Reach can be adjust-

ed in both directions by ETS.

UP: concealed version

AP: surface-mounted version

Package contents  

(Fig. 3.1, Fig. 3.4, Fig. 3.7, Fig. 3.10)

Product dimensions  

(Fig. 3.2, Fig. 3.5, Fig. 3.8, Fig. 3.11)

Product components  

(Fig. 3.3, Fig. 3.6, Fig. 3.9, Fig. 3.12)

Surface-mounting adapter

Load module

Connecting terminal

Programming button

Sensor module

HF 360-2 KNX detection zone 

(Fig. 3.13)
Hallway KNX detection zone  

(Fig. 3.14)

!

4.  Electrical connection

Surface-mounted connection (Fig. 4.1)

Concealed connection (Fig. 4.2) 

5.  Installation

•  Check all components for damage.

•  Do not use the product if it is dam-

aged.

•  Select an appropriate mounting 

location, taking the reach and 

motion detection into consideration. 

(Fig. 3.13/3.14)

•  Aim sensor in appropriate direction. 

Hallway KNX 

(Fig. 5.1)

Mounting procedure

•  Switch off power supply 

(Fig. 4.1/4.2)

Concealed mounting

•  Make plug connection. 

(Fig. 5.2)

•  Firmly screw load module into mount-

ing box. 

(Fig. 5.3)

•  Fit magnetic sensor module on frame.

 

(Fig. 5.4)

•  Switch ON power supply. 

(Fig. 5.4)

•  Make settings.

  

 "6. Function and settings"

Surface mounting

•  Mark drill holes and drill. 

(Fig. 5.5)

•  Screw load module into place. 

(Fig. 5.6)

•  Make plug connection. 

(Fig. 5.7)

•  Break out the mounting tab. 

(Fig. 5.8)

•  Fit surface-mounting adapter.

 

(Fig. 5.9)

•  Fit magnetic sensor module.

 

(Fig. 5.10)

•  Switch ON power supply. 

(Fig. 5.10)

•  Make settings.

  

 "6. Function and settings"

Technical specifications

 

– HF 360-2 dimensions (H × W × D):  

 

Surface-mounted installation:  

 

103 × 103 × 60 mm

 

Surface-mounted installation: 

 

123 × 123 × 57 mm

 

– Hallway dimensions (H × W × D):  

 

Concealed installation:  

 

103 × 103 × 66.5 mm

 

Surface-mounted installation: 

 

123 × 123 × 62 mm

 

– Power supply:  

 

KNX bus voltage 21-30 V

 

– Mounting height:  

2 - 4 m

 

– Angle of coverage:  

360°

 

– HF 360-2 reach:  

ø 12 m

 

– Hallway reach:  

24 × 3 m

 

– Sensor values:  

Light measurement,

 

 

Temperature: 0-40°C,

 

 

Relative humidity: 0-100%

 

– Outputs:  

 

 4 

× light output 

 

 

(ON/OFF, scenario dimming level),

 

 

Dimming level with effect light,

 

2× constant-lighting control with 

 

basic light level, 

 

 

HVAC, presence, temperature,

 

relative humidity, dew point,

 

logic gate,

 

comfort, anti-presence

 

– Time setting:  

 

30 seconds to 18:12:15 hours 

 

(hh:mm:ss), IQ mode

 

– Twilight setting:  

2-1000 lux

 

– Temperature range:  

0°C to +40°C

 

– IP rating:  

IP20

 

– Bluetooth frequency:  

2.4-2.48 GHz

 

– Bluetooth transmission power:  

 

 

5 dBm/3 mW

 

– HF 360/Hallway frequency:   5.8 GHz

 

– Transmission power:  

3 dBm/2 mW

Содержание 4007841058036

Страница 1: ...e 80 84 33442 Herzebrock Clarholz Tel 49 5245 448 188 www steinel de Contact www steinel de contact 110073767 10 2020 Technische nderungen vorbehalten Subject to technical modification without notice...

Страница 2: ...3 Textteil beachten Follow written instructions 3 1 HF 360 2 KNX UP 3 2 103 103 60 3 3 B C E D DE 7 GB 12 3 4 HF 360 2 KNX AP 3 5 123 123 57 3 6 A B C E D 3 7 Hallway KNX UP 3 8 103 103 66 5 3 9 B C E...

Страница 3: ...4 5 3 10 Hallway KNX AP 3 11 123 123 62 3 12 A B C E D 3 13 HF 360 2 KNX 2 5 m 12 m 3 14 Hallway KNX 4 2 4 m 25 m 3 m 4 1 LED Prog D I O 4 2 D I O 5 5 1 Hallway KNX 5 2 5 3 5 4 I O...

Страница 4: ...hrt werden Nur Original Ersatzteile verwenden Reparaturen d rfen nur durch Fach werkst tten durchgef hrt werden 3 HF 360 2 KNX Hallway KNX Bestimmungsgem er Gebrauch Sensor zur Deckenmontage im Innen...

Страница 5: ...Elektrischer Anschluss Anschluss Aufputz Abb 4 1 Anschluss Unterputz Abb 4 2 6 Funktion und Einstellungen Werkseinstellungen Siehe KNX Applikationsbeschreibung Testbetrieb Hinweis Die Applikationsbes...

Страница 6: ...tgeltliche Garantie gem den nachstehenden Bedingungen Wir leisten Garantie durch kostenlose Behebung der M ngel nach unserer Wahl Reparatur oder Austausch mangel hafter Teile ggf Austausch durch ein N...

Страница 7: ...3 13 Hallway KNX detection zone Fig 3 14 4 Electrical connection Surface mounted connection Fig 4 1 Concealed connection Fig 4 2 5 Installation Check all components for damage Do not use the product...

Страница 8: ...tructed sensor vision Check detection zone Lights do not switch OFF Switching threshold light level too high Reduce switching threshold light level Stay ON time elapsing Wait until stay ON time elapse...

Страница 9: ...h to make a claim please send your product complete and carriage paid with the original receipt of purchase which must show the date of purchase and product designation either to your retailer or cont...

Отзывы: