24
Please operate as follows:
1. Put the goods A on the scale pan, the weight window will display “1.500” (kg).
Input the unit price “5.00” (EUR/kg), the amount window will display “7.50”
(EUR);
2.
Press key [ADD], the adding indicator lamp will light up to indicate the scale is
under adding mode. The weight window will display “Add01”, and the amount
window will display “7.50” (EUR).
3.
Remove the goods A and wait for that the scale returns back to the weighing
mode;
4.
Put the goods B on the scale pan, the weight window will display “0.700” (kg),
then input the unit price “8.00” (EUR/kg), the amount window will display
“5.60” (EUR);
5. Press key [ADD], the adding indicator lamp will light up to indicate the scale
is under adding mode. The weight window will display “Add”, the unit price
window will display “02”, and the amount window will display“13.10”(EUR).
You can continue the adding operation as the above steps up to 99 times.
5.7 Clearing
Under the adding mode, press key [CLR], the unit price window will display “Clr”,
and the adding indicator lamp will be out which indicates that the scale is not in
adding status.
Under non-adding mode, if you input the wrong unit price, press key [CLR] and
input the correct unit price;
5.8 Zero
The weight window does not display “0.000” when unloaded, please press key
[ZERO] (within the range of ±60d).
5.9 Turning off the scale
Please press key [ON/OFF] and then pull power plug out.
6. ENVIRONMENT TEMPERATURE
Transportation and storage: -25
℃
~ +50
℃
Work: 0
℃
~ + 40
℃
7. ENVIRONMENT HUMIDITY
Transportation and storage: <70% R H (Non-dew)
Work: <90% R H (Non-dew)
8. BATTERY CHARGING
Please charge the storage battery in time after using it to avoid damage. The
charge time should be at least 1.2hours for using one hour. If the scale will be not
used for a long time, please do not forget to charge the scale for consecutive 24
hours every 2 or 3 months to avoid damage caused by self-discharge of storage
EN
25
battery (when the scale is connected to AC power, the system will charge the sto
-
rage battery automatically whether the scale is turned on or off. It is advised to
charge the electronic scale after it is turned off).
9. PRECAUTION
Never put the electronic scale in the rain or flush it with water. Particularly the
inner parts of the scale should avoid water.
It is forbidden to put the scale in the place with high temperature or humidity.
Avoid any strong shock or heavy weight. Don‘t put any article or give pressure
over maximum capacity on the scale pan even the scale is not in use.
Wrong wires connection of storage battery is forbidden.
Right connection: Red wire should be connected with red end; Black wire should
be connected with black end.
10. TROUBLESHOOTING
Failure
Description
Possible reason
Solution
AC indicator lamp
doesn‘t light up
Failure to connect
with the AC power
1. Poor contact
with the power
plug
2. Broken power
cord
3. Blown fuse
1. Insert the plug
well or change
socket
2. Change power
cord
3. Change fuse of
the same type
While using sto-
rage battery, no
display and sound
when turning on
No DC power in
the scale
1. Damaged sto
-
rage battery, no
voltage
2. Wire‘s poor
contact with sto-
rage battery
1. Change the
storage battery of
the same type
2. Contact wire
with battery well
(note: color cor-
responding)
Display “—Lb—”
with alarm sound
and turn itself off
automatically
Insufficient of vol
-
tage of battery
Too long use of
battery
Charge the scale
by connecting
with the AC power
supply
Unstable weighing
display
Insufficient of
voltage or get
damped
Continue to use
the battery when
the scale gives
alarm sound of in-
sufficient voltage
or the environ-
mental humidity
is too high
Charge the scale
for 10 hours by
connecting with
the AC power
supply or clean
the main board
and dry it
EN