Do not start up a damaged device or damaged accessories. Have them checked by the manufacturer or
its customer service or a qualified service technician.
Storage
As soon as the outside temperature permanently falls below +5 °C, the pump should be stored away for
the winter to prevent damage through ice formation (frost bursts).
Permanently installed water pipes do not necessarily have to be deinstalled. If the
location of the pump is protected against heavy soiling and strong weather influences, it
is sufficient to drain the water from the pump and the water pipes.
Winter storage
1. Pull the power plug of the pump
5
.
2. Close the shut-off valves or block the water flow to the pool lines.
3. Uninstall the pool lines and drain them.
4. Remove the drain screws
10
on the pump housing and completely empty the pump.
5. Screw the drain screws into the pump housing.
6. Thoroughly clean the device (see section "Cleaning").
7. Let the device dry completely after cleaning.
8. Store the device in a dry and frost-free location (>= +5 °C) without direct sunlight.
The device is stored.
Troubleshooting
Problem
Possible cause
Remedy
Air bubbles escape from the
injection nozzle or the pump emits
unusual noises.
The pump is sucking in air.
Check all hoses and gaskets for leaks.
Retighten the hose clamps.
Check the water level in the pool and fill
with more water if necessary until the
pool water covers the suction line
connection by approx. 2.5 - 5 cm (1 to 2
in).
The water level in the pool is too
low.
Raise the water level in the pool.
The prefilter basket (if present)
is clogged.
Empty the prefilter basket.
The suction line is out of place
or clogged.
Clean the suction line.
After the pump has been switched
on, the timer LED does not flash
and the pump does not start up.
The pump has no power.
Connect the pump's power plug to the
power supply. Check whether the fuse
has tripped.
The pump is defective.
Contact customer service.
24
Содержание 040090
Страница 2: ......
Страница 3: ...5 4 3 2 1 6 12 11 10 9 8 7 10 3 de ...