7
Fig 8
When the motor being installed to the left of gate , motor wires diagram as follows:
Terminal
③
connect the yellow wire from motor. and
Terminal
④
connect the red wire from motor.
Terminal
⑤
connect the blue wire from motor.
6.3.Connect to flashing light. (Please see Fig 9)
Please note : When you exchange red and yellow wire, please check if the motor can close
and stop normally. If can’t ,please up or down the “J1” to the opposite direction.
Note: “J1” includes two pcs short circuit caps, you need to adjust the caps simultaneously,
then it work.