12
Fig 15
As picture show, we can rotate "Open overload " potentiometer to adjust the motor open sensitivity of
blocked
A. High sensitivity : when the motor is rotation, will meet some minor resistance, then control board will
send a signal to let motor stop rotating.
B. Low sensitivity : when the motor is rotation, will meet greater resistance, then control board will send a
signal to let motor stop rotating.
C. As picture show
,
when pointer rotate to black part ,the control panel will quit this system
7.3 Gate close blocked detection:
Fig 16
As picture show, we can rotate "Close adjust " potentiometer to adjust the motor close sensitivity of
blocked
A. High sensitivity : when the motor is rotation, will meet some minor resistance, then control board will
send a signal to let motor stop rotating.
B. Low sensitivity : when the motor is rotation, will meet greater resistance, then control board will send a
signal to let motor stop rotating.
C. As picture show
,
when pointer rotate to black part ,the control panel will quit this system
8.
programming setting: