9
So, connect terminal
⑫
to the “+ “of photocell RX and TX.
connect terminal to
⑬
the “-“of photocell RX and TX.
6.6.Connect to start terminal. (Please see Fig 11)
When you don’t want to use the remote control to control the gate . Terminal
⑪
is for you connect some
external device , such push button, wired keypad, receiver etc.
Control gate open, stop ,close.
(Please see Fig 11)
Example for push button;
Terminal
⑪
and
⑬
connect to push button. Terminal
⑫
and
⑬
to supply power for push button
6.7.Connect to open device. (Please see Fig 12)
Terminal
⑯ is open only , for external device
, such push button, wired keypad, receiver etc.
Only control gate open
(Please see Fig 12)