3.4. Starting
Plug the power cord into the power source and set the power switch to ‘I’ to turn on
the power. Then, an initial screen with the current firmware number appears, and the
carriage checks for an oscillator connected to the oscillation socket. If the oscillator is
connected,
appears. After the control system is loaded, the
main menu from Fig. 4 appears.
Fig. 4.
Example of the main menu
Press and hold the knob F1 for about 3 seconds to go into the configuration
menu and set the welding parameters.
3.5. Programming
The ARC Runner welding carriage
allows defining up to 40 welding programs. After
going into the configuration menu, proceed as described in Fig. 5 to move among the
parameters from Tab. 1.
Fig. 5.
Configuration menu
Current operating state
Program
number
Unit of speed
Value of speed
Name of parameter. Rotate the knob F1 to change
among parameters listed in Tab. 1.
Value of parameter. Rotate the knob
F2 to change the value by the higher
step indicated in Tab. 1. Press and
rotate the knob F2 to change the
value by the lower step.
Unit of parameter. Can be changed from the
setting.