Operation and settings
BA_Activa Lift 2 Elektro ©_D_10_2010
24
www.steelcase-village.de
6.6.1 Reset after power switch on - Memory 4x operator panel
A reset process must be started in the following cases:
• Prior to placing the desk in service
• Every time that the connection to the mains supply, has been reestablished e.g. plugging in the
power cord.
WARNING
Danger of crushing and shearing!
Do not reach into the movement area.
CAUTION
Damage to the drives is possible!
If there is only movement on one side or if the lift movement is not uniform, inter-
rupt the reset process immediately.
Executing the
reset process
The "desktop up" function is blocked. The "Down" button is not active.
If the button is released before the process has been completely concluded, the reset process will be interrupt-
ed and must be restarted.
Incorrect
reset process
In the event that the reset process could not be successfully executed, proceed as follows:
Press the "Down" button and keep it
depressed until the lower desktop
position is reached and the desktop
clicks in place.
Press the "Up" and "Down" buttons
simultaneously and keep them
depressed for at least 5 seconds
Restart the reset process as described
above