background image

NEW WORK CEILING FAN

AND LIGHT FIXTURE BAR HANGER

INSTRUCTION SHEET

Individual Cat. Nos .... Bulk Pack Cat Nos.

56111CFB-BHL............... BPH-56111CFB ..................New Work Bar Hanger with 1/2" Deep Box. (Metallic Ceiling Fan Box)
54151CFB-BHL............... BPH-54151CFB ..................New Work Bar Hanger with 1-1/2" Deep Box. (Metallic Ceiling Fan Box)
R54151CFBBHL.............. RBPH-54151CFB................New Work Bar Hanger with 1-1/2" Deep Box. (Metallic Ceiling Fan Box)
54151-1/2-CFB-BHL....... BH-54151-1/2-CFB..............New Work Bar Hanger with 1-1/2" Deep Box. (Metallic Ceiling Fan Box with 1/2" conduit KO)
54171CFB-BHL............... BPH-54171CFB ..................New Work Bar Hanger with 2-1/8" Deep Box. (Metallic Ceiling Fan Box)
R54171CFBBHL.............. RBPH-54171CFB................New Work Bar Hanger with 2-1/8" Deep Box. (Metallic Ceiling Fan Box)
4070CFB-BHL................. BPH-4070CFB ....................New Work Bar Hanger with 2-3/8" Deep Box. (Non-Metallic Ceiling Fan Box)
CFB-BHL......................... BPH-CFB ............................New Work Bar Hanger without Box.

WARNING

DISCONNECT THE ELECTRICAL CIRCUIT SUPPLYING POWER  

TO THE OUTLET PRIOR TO INSTALLATION.

CAUTION

TO PREVENT INJURY, THE INSTALLER MUST ENSURE THAT 
THE HANGER IS SECURELY INSTALLED IN ACCORDANCE 
WITH THESE INSTRUCTIONS BEFORE MOUNTING OR 
CONNECTING A CEILING FAN OR LIGHT FIXTURE.

AFTER INSTALLATION OF THE HANGER, BE SURE TO 
FOLLOW ALL MOUNTING INSTRUCTIONS WITH THE CEILING 
FAN OR LIGHT FIXTURES.

CAUTION

DO NOT EXCEED MAXIMUM WEIGHT RATINGS

FOR 4070CFB-BHL, BPH-4070CFB:
MAX LIGHT FIXTURE = 50 LBS.
MAX CEILING FAN = 35 LBS. (INCLUDES ACCESSORIES)

FOR 56111CFB-BHL, BPH-56111CFB, 54151CFB-BHL, 
BPH-54151CFB, 54151-1/2-CFB-BHL, R54151CFBBHL, 
BH-54151-1/2-CFB, 54171CFB-BHL, R54171CFBBHL & 
BPH-54171CFB:
MAX LIGHT FIXTURE = 200 LBS.
MAX CEILING FAN = 70 LBS.

FOR CFB-BHL & BPH-CFB (Bar Hanger Only):
LOAD RATING IS ACCORDING TO SPECIFIC CEILING BOX TYPE

INSTALL THIS BAR HANGER SUPPORT ONLY IN 
ACCORDANCE WITH APPLICABLE NATIONAL AND LOCAL 
BUILDING AND ELECTRICAL CODES.

READ ALL INSTRUCTIONS AND WARNINGS CAREFULLY BEFORE PROCEEDING!

— CONSULT A QUALIFIED ELECTRICIAN IF YOU HAVE 

ANY QUESTIONS. —

IMPORTANT SAFETY NOTICE:  

USE ONLY METALLIC BOX AND 

SCREWS PROVIDED IN KIT.  DO NOT SUBSTITUTE!

INSTALLATION INSTRUCTIONS:

1.  Expand the bar hanger to the length of spacing between the wood ceiling joists. Position the end-plates in 

accordance with the model selected (See Figure 1 & Figure 2).

Figure 1

Figure 2

For 1/2 inch deep ceiling box,       

position end-plates flush with    

bottom edge of joist.

Part No.:  56111CFB-BHL & BPH-56111CFB

Reference drywall flush with bottom of box.

END-PLATE

For deep ceiling box, see Table 1 
for correct position of end-plates 

above bottom edge of joist.

Reference drywall flush with bottom of box.

DEPTH

BOTTOM EDGE

OF JOIST

BOTTOM EDGE

OF JOIST

END-PLATE

Catalog Number

4070CFB-BHL, R54151CFBBHl & BPH-4070CFB

54151CFB-BHL & BPH-54151CFB

54151-1/2-CFB-BHL & BH-54151-1/2-CFB

54171CFB-BHL, R54171CFB-BHL & BPH-54171CFB

Depth

1-7/8 inch

1 inch

1-5/8 inch

Table 1

TA02408  D    Page 1 of 2

Отзывы: