Copyright - All Information Reserved -
!
ϼ݂υտ
!
Rear View - MS18-DC2403-8CM1
24V DC 3A 84W 8 Channel at 250mA Max. Each
Rear View - MS18-DC481A5-8CM1
48V DC 1.5A 84W 8 Channel at 125mA Max. Each
All Units Were Tested Under LVD IEC/EN 60950-1, PSE J60950, EMC EMI
EN55022 (EN61000-3-2,3) & EMS EN55024 (EN61000-4-2,3,4,5,6,8,11) Standards
Front View - MS18-DC1206-8CM1
12V DC 6A 84W 8 Channel at 500mA Max. Each
Installation :
Do place the power cable properly so it will not be steeped in or tripped over.
Do not place the AC power supply in a location where it is:
Subject to extreme high or low ambient temperature
l
Subject to direct sunlight or near a heat source such as oven, stove etc.
l
Subject to mechanical vibration or shock
l
Subject to excessive amount of dust
l
STEED MAGNET PRODUCTS ENTERPRISE CO., LTD.
warrant this product to be free from defects
in material and workmanship for a period of 90 days from the date of purchase from our authorized
dealers. Should the product require service during this period, all labor and parts used to effect repairs
will be supplied free of charge.
reserve the right to determine whether damage has been
STEED
occasioned by accident, misuse, or improper installation whereby the warranty would be void.
In the event of a defect occurring during warranty period, the original purchaser may return the defect
unit along with suitable proof of purchase date
and a full
(i.e. receipt, docket, credit card slip etc.)
description of the defect to the dealer you purchased. All freight charges incurred for transportation by
the dealer or
are the purchaser's responsibility.
STEED
W
ARRANTY
l
Copyright - All Information Reserved !
MS-DC
(Desktop Type)
Series
l
Copyright - All Information Reserved !
Multiple Output Security CCTV Power Supply
Instruction Manual
The Power Master
R
Notes: All rights reserved. Do not reprint without written permission.
l
Steed reserves the right to modify products without notice.
l
File No.
MNL-MS-DC-Prime
Issue No.
Revision
Ori
0814
P
& I
RECAUTION
MPORTANT NOTICE
!
Moisture :
If the device is moved from a cold place to a warm room, condensation may occur
l
inside. To avoid damage please allow the device to reach room temperature before
using it.
On safety :
Before operating the system, carefully check the specifications of your appliance. Be
l
sure that the operating voltage of your appliance is identical with your local mains.
The power supply is for indoor use only! Keep it in dry environment.
l
Do not use the power supply if there are signs of any damage in housing, plug or cord.
l
The unit is not disconnected from the AC power source (mains) as long as it is
l
connected to the wall outlet, even if the unit itself has been shutdown.
Unplug the system from the wall outlet if it is not to be used for an extended period of
l
time. To disconnect the cord by grasping the plug. Never pull the cord itself.
Should any liquid or solid object fall into the system, unplug the system’s power cord
l
and have the system checked by qualified personnel before operating it any further.
Do not open the device or make unauthorized modifications to the circuit inside.
l
Repair works must only be carried out by qualified servicing personnel.
l
:
Operation
Make sure the current and voltage of the equipment matches that of the outlet.
l
For safety, if the output current is too high, the unit will automatically shut down.
l
To prevent damage, not to drop or it may cause a mechanical shock to the unit.
l
After using, disconnect the unit from the wall outlet and the equipment.
l
Disconnect the unit from the AC outlet by pulling on the plug. Do not pull on the cord.
l
To avoid short-circuiting, do not allow the output screw terminals of the unit or input
l
connector plug to touch any metal object.
To ensure proper operation, read this manual thoroughly before using this product.
After reading, be sure to keep it where it can be seen by all those who use the product.
Cleaning :
Do remove any power sources from the unit before attempting any cleaning or
l
maintenance checking for preventing from being electrical shocked.
Clean the unit with a soft, dry cloth. If the unit is very dirty, wipe it off with a soft cloth
l
lightly moistened with a mild detergent solution, and then wipe with a soft dry cloth.
If you use any chemical cleaner, observe the instructions provided with the product.
l
If the cabinet of the unit is splashed with any type of solvent such as insecticide, or
l
remains in contact for a long time with cable rubber or vinyl, the finish of the cabinet
may be damaged.
Rear View
Model MS -DC1206-8CM1
18
Front View
Model MS -DC1206-8CM1
18
S
E
1
2
3
4
5
6
7
8
Indicator of Slave Outputs of Regulated 12V at 500mA Max. Each Channel
LED STATUS INDICATION
GREEN = Output Is In Powering Loads Normally
YELLOW = Power On and In Standby Normally
OFF = Power Off or Mains Thermal Shutdown
1
2
3
4
5
6
7
8
Indicator of Slave Outputs of Regulated 24V at 250mA Max. Each Channel
LED STATUS INDICATION
GREEN = Output Is In Powering Loads Normally
YELLOW = Power On and In Standby Normally
OFF = Power Off or Mains Thermal Shutdown
Model: MS
DC2403-8CM1
-
18
Multiple Outputs
Security CCTV Power Supply
The Security Power Master
CB LVD & EMC APPROVED
R
1
2
3
4
5
6
7
8
Indicator of Slave Outputs of Regulated 48V at 125mA Max. Each Channel
LED STATUS INDICATION
GREEN = Output Is In Powering Loads Normally
YELLOW = Power On and In Standby Normally
OFF = Power Off or Mains Thermal Shutdown
Model: MS
DC481A5-8CM1
-
18
Multiple Outputs
Security CCTV Power Supply
The Security Power Master
CB LVD & EMC APPROVED
R
Available From:
Prime-co Pte Ltd.
7030 Ang Mo Kio Ave 5 #03-27 Northstar
@ AMK, Singapore 569880
l
l
Tel:
Fax:
65-6252-1221
65-6252-4700
Email:
www.prime-co.com.sg
Web-site:
Manufactured By:
Steed Magnet Products Ent Co Ltd
.
.,
.
in Taiwan, R.O.C.
For Distributing By:
Prime-co Pte Ltd.
in Singapore
Front View - MS18-DC2403-8CM1
Front View - MS18-DC481A5-8CM1
O
I
FUSE
48V
125mA Max. Each Channel
8
7
6
5
4
3
2
1
REGULATED SLAVE OUTPUTS
RED
BLK
AC INPUT
100V - 240V
~
1-0.5A 50/60Hz
l
Replace only
w/2.50A 250V
5x20mm type
Fast blow fuse
AC POWER
OFF
ON
l
Label #LB-481A5-8-AF
WARNING
High Voltage !
MASTER OUTPUT
Output Voltage: 55.2V
l
l
Output Current:1.5Amps
(Total, Including The
8 Channel of Slave Outputs)
l
Build in 3.0A 58V Fuse
Replace only with same
l
Rating & Blade Auto Fuse
DC FUSE
CAUTION
l
Polarity Are Critical !
l
Don’t Overload Any Outputs
Made in Taiwan Label #LB-481A5-8-M
l
RED
BLK
AC INPUT
AC FUSE
F
USE
PUSH
O
I
FUSE
24V
250mA Max. Each Channel
8
7
6
5
4
3
2
1
REGULATED SLAVE OUTPUTS
RED
BLK
AC INPUT
100V - 240V
~
1-0.5A 50/60Hz
l
Replace only
w/2.50A 250V
5x20mm type
Fast blow fuse
AC POWER
OFF
ON
l
Label #LB-2403-8-AF
WARNING
High Voltage !
MASTER OUTPUT
Output Voltage: 27.6V
l
l
Output Current: 3Amps
(Total, Including The
8 Channel of Slave Outputs)
l
Build in 5.0A 32V Fuse
Replace only with same
l
Rating & Blade Auto Fuse
DC FUSE
CAUTION
l
Polarity Are Critical !
l
Don’t Overload Any Outputs
Made in Taiwan Label #LB-2403-8-M
l
RED
BLK
AC INPUT
AC FUSE
F
USE
PUSH