background image

Copyright - All Information Reserved -

!

ϼ݂υտ

!

Rear View - MS18-DC2403-8CM1

24V DC 3A 84W 8 Channel at 250mA Max. Each

Rear View - MS18-DC481A5-8CM1

48V DC 1.5A 84W 8 Channel at 125mA Max. Each

All Units Were Tested Under LVD IEC/EN 60950-1, PSE J60950, EMC EMI

EN55022 (EN61000-3-2,3) & EMS EN55024 (EN61000-4-2,3,4,5,6,8,11) Standards

Front View - MS18-DC1206-8CM1

12V DC 6A 84W 8 Channel at 500mA Max. Each

Installation :

Do place the power cable properly so it will not be steeped in or tripped over.
Do not place the AC power supply in a location where it is:

Subject to extreme high or low ambient temperature

l

Subject to direct sunlight or near a heat source such as oven, stove etc.

l

Subject to mechanical vibration or shock

l

Subject to excessive amount of dust

l

STEED MAGNET PRODUCTS ENTERPRISE CO., LTD.

warrant this product to be free from defects

in material and workmanship for a period of 90 days from the date of purchase from our authorized
dealers. Should the product require service during this period, all labor and parts used to effect repairs
will be supplied free of charge.

reserve the right to determine whether damage has been

STEED

occasioned by accident, misuse, or improper installation whereby the warranty would be void.
In the event of a defect occurring during warranty period, the original purchaser may return the defect
unit along with suitable proof of purchase date

and a full

(i.e. receipt, docket, credit card slip etc.)

description of the defect to the dealer you purchased. All freight charges incurred for transportation by
the dealer or

are the purchaser's responsibility.

STEED

W

ARRANTY

l

Copyright - All Information Reserved !

MS-DC

(Desktop Type)

Series

l

Copyright - All Information Reserved !

Multiple Output Security CCTV Power Supply

Instruction Manual

The Power Master

R

Notes: All rights reserved. Do not reprint without written permission.

l

Steed reserves the right to modify products without notice.

l

File No.

MNL-MS-DC-Prime

Issue No.

Revision

Ori

0814

P

& I

RECAUTION

MPORTANT NOTICE

!

Moisture :

If the device is moved from a cold place to a warm room, condensation may occur

l

inside. To avoid damage please allow the device to reach room temperature before
using it.

On safety :

Before operating the system, carefully check the specifications of your appliance. Be

l

sure that the operating voltage of your appliance is identical with your local mains.

The power supply is for indoor use only! Keep it in dry environment.

l

Do not use the power supply if there are signs of any damage in housing, plug or cord.

l

The unit is not disconnected from the AC power source (mains) as long as it is

l

connected to the wall outlet, even if the unit itself has been shutdown.

Unplug the system from the wall outlet if it is not to be used for an extended period of

l

time. To disconnect the cord by grasping the plug. Never pull the cord itself.

Should any liquid or solid object fall into the system, unplug the system’s power cord

l

and have the system checked by qualified personnel before operating it any further.

Do not open the device or make unauthorized modifications to the circuit inside.

l

Repair works must only be carried out by qualified servicing personnel.

l

:

Operation

Make sure the current and voltage of the equipment matches that of the outlet.

l

For safety, if the output current is too high, the unit will automatically shut down.

l

To prevent damage, not to drop or it may cause a mechanical shock to the unit.

l

After using, disconnect the unit from the wall outlet and the equipment.

l

Disconnect the unit from the AC outlet by pulling on the plug. Do not pull on the cord.

l

To avoid short-circuiting, do not allow the output screw terminals of the unit or input

l

connector plug to touch any metal object.

To ensure proper operation, read this manual thoroughly before using this product.
After reading, be sure to keep it where it can be seen by all those who use the product.

Cleaning :

Do remove any power sources from the unit before attempting any cleaning or

l

maintenance checking for preventing from being electrical shocked.

Clean the unit with a soft, dry cloth. If the unit is very dirty, wipe it off with a soft cloth

l

lightly moistened with a mild detergent solution, and then wipe with a soft dry cloth.

If you use any chemical cleaner, observe the instructions provided with the product.

l

If the cabinet of the unit is splashed with any type of solvent such as insecticide, or

l

remains in contact for a long time with cable rubber or vinyl, the finish of the cabinet
may be damaged.

Rear View

Model MS -DC1206-8CM1

18

Front View

Model MS -DC1206-8CM1

18

S

E

1

2

3

4

5

6

7

8

Indicator of Slave Outputs of Regulated 12V       at 500mA Max. Each Channel

LED STATUS INDICATION

GREEN = Output Is In Powering Loads Normally

YELLOW = Power On and In Standby Normally

OFF = Power Off or Mains Thermal Shutdown

1

2

3

4

5

6

7

8

Indicator of Slave Outputs of Regulated 24V       at 250mA Max. Each Channel

LED STATUS INDICATION

GREEN = Output Is In Powering Loads Normally

YELLOW = Power On and In Standby Normally

OFF = Power Off or Mains Thermal Shutdown

Model: MS

DC2403-8CM1

-

18

Multiple Outputs

Security CCTV Power Supply

The Security Power Master

CB LVD & EMC APPROVED

R

1

2

3

4

5

6

7

8

Indicator of Slave Outputs of Regulated 48V       at 125mA Max. Each Channel

LED STATUS INDICATION

GREEN = Output Is In Powering Loads Normally

YELLOW = Power On and In Standby Normally

OFF = Power Off or Mains Thermal Shutdown

Model: MS

DC481A5-8CM1

-

18

Multiple Outputs

Security CCTV Power Supply

The Security Power Master

CB LVD & EMC APPROVED

R

Available From:

Prime-co Pte Ltd.

7030 Ang Mo Kio Ave 5 #03-27 Northstar
@ AMK, Singapore 569880

l

l

Tel:

Fax:

65-6252-1221

65-6252-4700

Email:

[email protected]

www.prime-co.com.sg

Web-site:

Manufactured By:

Steed Magnet Products Ent Co Ltd

.

.,

.

in Taiwan, R.O.C.
For Distributing By:

Prime-co Pte Ltd.

in Singapore

Front View - MS18-DC2403-8CM1

Front View - MS18-DC481A5-8CM1

O

I

FUSE

48V

125mA Max. Each Channel

8

7

6

5

4

3

2

1

REGULATED SLAVE OUTPUTS

RED

BLK

AC INPUT

100V - 240V

~

1-0.5A 50/60Hz

l

Replace only
w/2.50A 250V
5x20mm type
Fast blow fuse

AC POWER
OFF

ON

l

Label #LB-481A5-8-AF

WARNING

High Voltage !

MASTER OUTPUT

Output Voltage: 55.2V

l
l

Output Current:1.5Amps
(Total, Including The
8 Channel of Slave Outputs)

l

Build in 3.0A 58V Fuse
Replace only with same

l

Rating & Blade Auto Fuse

DC FUSE

CAUTION

l

Polarity Are Critical !

l

Don’t Overload Any Outputs

Made in Taiwan Label #LB-481A5-8-M

l

RED

BLK

AC INPUT

AC FUSE

F

USE

PUSH

O

I

FUSE

24V

250mA Max. Each Channel

8

7

6

5

4

3

2

1

REGULATED SLAVE OUTPUTS

RED

BLK

AC INPUT

100V - 240V

~

1-0.5A 50/60Hz

l

Replace only
w/2.50A 250V
5x20mm type
Fast blow fuse

AC POWER
OFF

ON

l

Label #LB-2403-8-AF

WARNING

High Voltage !

MASTER OUTPUT

Output Voltage: 27.6V

l
l

Output Current: 3Amps
(Total, Including The
8 Channel of Slave Outputs)

l

Build in 5.0A 32V Fuse
Replace only with same

l

Rating & Blade Auto Fuse

DC FUSE

CAUTION

l

Polarity Are Critical !

l

Don’t Overload Any Outputs

Made in Taiwan Label #LB-2403-8-M

l

RED

BLK

AC INPUT

AC FUSE

F

USE

PUSH

Отзывы: