NOTICE!
Risk of damage to the inverter and the modules.
Connect the opposing connectors for the DC
connections to the DC cable, observing the correct
polarity.
Attach the connector plug counterparts to the DC cable
according to the manufacturer's instructions; see Appendix.
4.5 Preparing the data connection cable
If a data connection is required, use a standard RJ45 cable
(patch cable, Cat5) or construct an alternative data
further information on page 28).
4.6 Connecting the inverter inverter and switching the AC on
DANGER!
Risk of death by electrocution! Observe the hazard
during installation’ on page 31.
NOTICE!
–
Between the data connection cables (RS485/
Ethernet) and the DC/AC lines, maintain a
distance of 200 mm, to avoid interference in the
data transmission.
–
The protection class IP65 for type coolcept-x is
only ensured if the AC and DC plugs are plugged
in and the RJ45 sockets are sealed with sealing
caps.
1.
If necessary, establish the data connection:
n
Connect the inverters and the master with data
connection cables.
n
On the last inverter, switch on the termination (slide
switch).
2.
Seal open RJ45 sockets with sealing caps.
3.
Forcefully press the plug connector mating piece (DC cable)
into the DC connection on the inverter until it audibly locks in
place.
4.
Plug the AC connector onto the coupling on the inverter, until
the plug audibly locks in place.
EN
747,431 | Z09.2 | 18/02/2016
38
Содержание coolcept StecaGrid 1500
Страница 1: ...Installation and operating instructions EN coolcept coolcept x 747 431 Z09 2 2016 02 18...
Страница 57: ...Fig 20 Email confirming successful registration EN 747 431 Z09 2 18 02 2016 57...
Страница 85: ...Appendix EN 747 431 Z09 2 18 02 2016 85...
Страница 93: ...747 431 Z09 2 2016 02 18...
Страница 94: ......