background image

_________________________________________________________________________________

TOLO SAUNA

[email protected]

www.tolosauna.com

1

Steamtec AIO

Steam Generator Manual

DO NOT use locking pliers to over tight the

DRAIN PIPE connection

Please read the manual carefully before installation

and keep the manual for further reference

Содержание AIO

Страница 1: ...__________________ TOLO SAUNA info tolosauna com www tolosauna com 1 Steamtec AIO Steam Generator Manual DO NOT use locking pliers to over tight the DRAIN PIPE connection Please read the manual carefully before installation and keep the manual for further reference ...

Страница 2: ...Cautions 9 6 1 Installation cautions 9 6 2 Installation of steam generator body 9 6 2 1 Cautions 9 6 2 2 Installation 9 6 3 Installation of Central function box 10 6 4 Installation of controller and temperature sensor 12 6 5 Installation of pipeline 16 6 6 Installation of electrical circuit 18 6 6 1 Power Supply 19 6 6 2 Wire Diagram 19 7 Functions And Operation 25 7 1 Control panel display items ...

Страница 3: ...ntity Steam generator in stainless steel housing 1pc Controller housing box waterproof touch screen 1set Central function box 1pc Central function box power cord 1pc 3 4 Full bore straight auto drain valve 1pc Control cable length 5 m central function box controller 1pc Temp sensor with box length 5 m central function box sensor end position 1pc Central function box cable steam generator central f...

Страница 4: ...ture steady performance and convenient installation This steam generator can work with the steam room to form a whole steam bath system The steam bath is for removing tiredness relaxing muscles and stimulating blood circulation For proper installation operation maintenance and the safety of customer as well please read all instructions carefully and keep this manual for further reference Figure 1 ...

Страница 5: ...ly and the power supply power wire fuse and breaker must comply with the nameplate on the unit and table 2 in this manual The solenoid valve can endure maximum 0 8MPa 8kg cm2 water pressure To protect the solenoid valve from extremely high water pressure please turn down the inlet slightly or install water pressure relieving valve Do not install saddle backed or needle valves on the inlet Please d...

Страница 6: ... 22 7 3 2 5 32 4 6 3 380 415 9 1 5 1 5 16 TOLO 60 6 0 1 3 2 0 215 240 27 3 3 4 0 40 5 7 3 380 415 9 1 5 1 5 16 TOLO 70 7 0 1 2 2 5 1 2 0 215 240 31 8 3 6 0 40 5 5 8 475 185 450 3 380 415 10 6 5 2 5 16 TOLO 75 7 5 1 3 2 5 215 240 33 75 3 6 0 60 6 5 9 3 380 415 11 25 5 2 5 16 TOLO 90 9 0 3 6 1 5 380 415 13 6 5 2 5 16 8 11 TOLO 105 10 5 3 3 1 5 3 2 0 380 415 15 9 5 2 5 25 9 12 TOLO 120 12 0 3 6 2 0 3...

Страница 7: ... 4 0mm2 How to choose the right KW steam generator Step One Calculate the steam room m Length Width Height in meter 1 feet 0 3048 meter 1 inch 0 0254 meter Step Two Check your steam room materials If Acrylic steam generator KW steam room m If Ceramic Tile steam generator KW 1 30 X steam room m If All Glass tile or Glass Block Walls steam generator KW 1 35 X steam room m If Porcelain tile steam gen...

Страница 8: ...lling range Dimension mm AIO 1 60 or long term CH 6 60 43 140 35 60 C 95 140 103 103 45 Table 3 Notes AIO Controller can be installed inside the steam room However we recommend you to install the controller outside the steam room to extend its service life Figure 4 AIO controller 1 Steam outlet 2 Safety valve 3 Heating elements 4 Solenoid water inlet valve 5 Drain valve 6 Drain pipe 7 High tempera...

Страница 9: ...ace Do not install the generator near to inflammables such as oil paint diluents and fuel Be alert to the steam pipeline and safety valve since the high temperature of steam is dangerous to customers Generator must be level installed The generator should be installed in a dry and well ventilated place It can be installed either on the wall or on the ground but must be well fixed Install the genera...

Страница 10: ...install steam generator 6 3 Installation of Central function box Central function box should be installed near to the steam generator as the cable for connecting the central function box and the steam generator is only 50 cm Please hang the central function box on the wall It need separate power supply it s provided with plug Connect the function equipment Like aroma pump color lights etc to the c...

Страница 11: ...0 Descaling pump 11 Connector to the steam generator 12 Power supply 12V DC Connect the steam generator with the central function box by using the 12 core cable we provided Please install the central function box near to the steam generator as close as possible Please note the 12 core cable can t be extended and only from original factory is allowable NOTES indicators explanation D34 Main board po...

Страница 12: ...ions The control wire and temperature wire should not be parallel to or intersect with the power wire The temperature sensor should NOT be installed on the side of the wall which is behind the door 6 4 2 Installation of controller The controller should be installed with height of 1 2 m inside or outside the steam room but nearby or other place where easy to operate Firstly follow below 4 steps for...

Страница 13: ..._______________________ TOLO SAUNA info tolosauna com www tolosauna com 13 95 1 95 1 First step open the hole on wall 95 95MM Depth 34MM 34 Second step Housing box into the wall at the gap horizontal installation The gap for Positioning The gap for Positioning ...

Страница 14: ...__________________________________ TOLO SAUNA info tolosauna com www tolosauna com 14 Third step make the tiles cover the gap and keep in line with tiles Forth step insert the controller into the housing box Tile molding surface Tile molding surface ...

Страница 15: ...n work automatically according to the pre set temperature and maintain the room temperature constant The installation height of the sensor should be about 1 2 1 5 m from ground Please drill a hole diameter 16mm and then nail down the sensor in the steam room Refer to figure 10 pull the sensor wire through the conduit then connect to the central function box wirepipe control wire control wire wirep...

Страница 16: ...f pipeline Figure 11 3kw 13 5kw pipe connection Figure 12 15kw 24kw pipe connection 3kw 13 5kw Service hole 1 2 Steam outlet 3kw 6kw 1 2 7kw 13 5kw 3 4 Safety valve 1 2 Water inlet 1 2 Drain outlet 3 4 Power supply for drain valve 15kw 24kw Service hole 1 2 Steam outlet 3 4 Safety valve 1 2 Water inlet 1 2 Drain outlet 3 4 Power supply for drain valve ...

Страница 17: ...ipe of the generator The pipe should be less than 3 meters long and minimize the number of elbows otherwise heat isolating methods should be implemented For 3KW 6KW steam generator steam outlet is 1 2 please AT LEAST use 1 2 steam pipe must be stainless steel pipe or copper pipe For 7KW 13 5KW steam generator steam outlet is 3 4 please AT LEAST use 3 4 steam pipe must be stainless steel pipe or co...

Страница 18: ...onnect the earth wire to the null wire Only the original parts and elements from our factory are allowed to be used in installation operation maintenance and repair After the installation of the pipeline and electrical circuits careful checking must be performed before switch on the generator The generator has been carefully installed checked and tested in factory thus user only need to install th...

Страница 19: ... the null wire to the terminal labeled as N and connect the earth wire to the terminal labeled as Please see figure 14 Figure 14 Single phase 215 240V Three phases 380 415V 50 60Hz power supply Connect the 3 live wires to the terminal labeled as L1 L2 and L3 respectively connect the null wire to the terminal labeled as N and connect the earth wire to the terminal labeled as Please see below figure...

Страница 20: ...________________________ TOLO SAUNA info tolosauna com www tolosauna com 20 AIO 3KW 4KW European 215 240 V single phase Figure 16 2503 N L term inal blocks N1 N2 L2 L1 heating element 2 NO COM heating element 1 O ver heat protection cathode 5 4 6 1 3 N O COM ...

Страница 21: ...o tolosauna com www tolosauna com 21 2506 COM NO 3 1 6 4 5 cathode O v er heat protection heating element 2 heating element 1 N COM NO NO COM heating element 3 L1 L2 L3 termina l blocks N L t erm ina l b locks 4 5kw 5kw 6kw 7kw 7 5kw European 215 240V Single Phase or 380 415V 3Phases Figure 17 AIO ...

Страница 22: ...olosauna com 22 2506 cathode NO COM COM NO 5 4 6 1 3 NO COM NO COM COM NO 5 4 6 1 3 NO COM Over heat protection L1 L2 L3 N L3 L2 L1 heating element 5 heating element 6 heating element 4 heating element 3 heating element 2 heating element 1 terminal blocks AIO 9kw 10 5kw 12kw 13 5kw European 380 415V 3 Phases Figure 18 ...

Страница 23: ...com www tolosauna com 23 terminal blocks heating element 1 heating element 2 heating element 3 heating element 4 heating element 6 heating element 5 L1 L2 L3 N L3 L2 L1 Over heat protection 4506 NO COM COM NO 5 4 6 1 3 NO COM NO COM COM NO 5 4 6 1 3 NO COM cathode AIO 15kw European 380 415V 3 Phases Figure 19 ...

Страница 24: ...5 4 6 1 3 NO COM NO COM COM NO 5 4 6 1 3 NO COM NO COM COM NO 5 4 6 1 3 NO COM 4506 Over heat protection Over heat protection L1 L2 L3 N L3 L2 L1 heating element 9 heating element 7 heating element 8 heating element 5 heating element 4 heating element 2 heating element 1 heating element 3 heating element 6 Figure 20 AIO 16 5kw 18kw 22 5kw 24kw European 380 415V 3 Phases ...

Страница 25: ...display items COLOURED LIGHTS SALT SPRAY ON OFF SET AROMA PUMP FAN Figure 21 AIO Controller Each first touch is for waking up the touch panel Selection key SET Function key FAN AROMA PUMP COLOURED LIGHTS SALT SPRAY ON OFF Working time range 1 60 minutes or continuous CH The default working time is 45 minutes Temperature setting range 35 60 C The default temperature is 43 C ...

Страница 26: ...e water level S2 2 Lock the color S10 Humidity instructions S18 Low water level S3 APP S11 Working time S19 Water tank temperature S4 Heating instructions S12 Celsius degree S5 Domestic model S13 Heat preservation instructions S20 Drain valve S6 Commercial model Table 4 S1 Exhaust fan Fan ON OFF button FAN The working time setting is from 1 60 minutes after time arrived will stop working automatic...

Страница 27: ...ocal area network WLAN Open the App in your iPhone or Android phone then you can operate the steam generator by your Phone now More information please browse Steamtec Sauna App operation guide After your Phone connect well to steam generator the all in one controller screen will show App S4 Heating instructions S4 lights steam generator is heating S5 Domestic model S5 lights steam generator is und...

Страница 28: ...30 minutes S8 Aroma pump S8 lights aroma pump is on There has A B aroma pump with 2 kinds of aroma oil Change A B pump at SET Pump s default working time is 5 seconds then waiting time is 5 minutes The working time is non adjustable If you like the more heavy fragrance please restart it again and again S9 Temperature instructions S9 shows the steam room temperature value Set the temperature at SET...

Страница 29: ...rking time is from 1 60 minutes and non stop S12 Celsius degree S12 shows the steam room temperature in Celsius degree S13 Heat preservation instructions S13 lights shows the room temperature reaches 2 C higher than your setting value then all heating elements stop working steam generator under heat preservation state S14 Descaling S14 lights steam generator is off going into descaling model Desca...

Страница 30: ...ON mean it is draining the water now 7 2 Auto Functions i Auto filling Inlet valve will open automatically once the system is started and fill in water automatically until the water level reaches maximum level If water level is still lower than the minimum water level 10 minutes after it indicates faults of the water supply system so all heating elements will stop working If the screen display it ...

Страница 31: ...n Plug on the wires make sure the heating elements are properly connected before put on the element access cover ii Replace the main board The main board is inside the central function box If need to replace the main board please contact your dealer iii Replace the sub board Switch off the steam generator and remove the U shape cover when the generator completely cools down Unplug all the wires on...

Страница 32: ...or is higher than 60 C Check whether the room temperature is above 60 C the code should disappear after the room temperature drops below 60 C Otherwise check the connection of the sensor E Water supply or water fill in faults the heating elements will not heat up or stop heating up Check whether the water inlet solenoid valve works check the valve on the water pipeline or water supply source check...

Страница 33: ...er properly but does not heat up please check the connection wire between main circuit board and the sub board the relays on sub board and heating elements iii If water comes out from the steam outlet pipe seriously please clean or change the outlet solenoid valve iv If the system keeps on heating up even if the current temperature is more than 2 C above the setting value with the indicator on car...

Страница 34: ...nside the steam room controller warranty is for 1 year 5 Our company has the right to decide whether to repair or to change Approval must be obtained from our company before shipping back the product The customer has to pay for the transportation fee and any parts fee beforehand 6 Any clause mentioned in the manual is not covered by the warranty 7 This warranty does not cover any defect malfunctio...

Страница 35: ...quid through service hole and let it stay in water tank for 4 8 hours then flush How frequently should descaling be done For home use at least once per month For commercial use at least once per week What descaling liquid can be used TOLO acid Vinegar or lemon juice mix with water and make concentration around 10 Or can use edible acid cleaning solution or powder 11 Appendix Parameter Of Special M...

Страница 36: ..._______________________________________________________________ TOLO SAUNA info tolosauna com www tolosauna com 36 MAINTENANCE RECORD Regular descaling records Model _______________________ Date Person Detail description ...

Отзывы: