background image

1½“ Hole

located four feet

from the floor

Double-Sided

Adhesive Pad

IMPORTANT: 

Run the 

Control Cable through 
a ¾” conduit.

Coupler

To Steam Generator

Modular Jacks:

All four modular jacks are

identical and work in

any combination.

Connect to any jack.

¾" Conduit

To Control

C

US

®

SHOWER

STEAM

SHOWER

STEAM

1

1

2

2

9:31

IM

IMPORTANT: The TSC-450 Control will only function with the current TSG steam generators.

Installation Instructions

Steambath Control

Installation Instructions

Model: TSC-450

Control Features

1.

  Timer control

2. 

Temperature control

3.

  Multiple user settings

4.

  AudioSense™ control

5. 

ChromaSense™ control

6. 

AromaSense™ control

7.

 ShowerSense™ control

8. 

Other Miscellaneous settings

NOTE: For more details see separate operating instructions.

IMPORTANT: Control MUST be installed inside the steam room 
for proper operation of the system.

1.

 Pre-Installation - Control Location

The TSC-450 Control must be installed inside the steam 
room. For convenience the recommended height from the 
floor is four feet. If a TSSH is also installed we recom-
mend a height of 4½" feet when used for both steam and 
shower. Provide a 1½" hole in the wall at this location (see 
Figure 1).

IMPORTANT: Multi-conductor cable must be installed so 
that the end will not be buried inside the wall. The unit will 

Total Sense Touch Control

Figure 1

Figure 2 - Cable Installation on Generator

12/15

Pub. No. 290-D

- 1 -

Required Inside 
Installation 
TSC-450 Control. 
Locate away from the 
direct line of shower 
spray and do NOT 
locate above 
steamhead.

Cleaning Instructions: Use a damp cloth and mild soap. 
Do NOT use abrasive cleaners which might scratch the 
surface or the base of the control.

not operate unless the control is installed.

2. 

Electrical Rough-in

Remove the multi-conductor cable from the control 
packing box. Carefully route the multi-conductor control 
cable from the steam generator to the TSC-450 located 
inside the steamroom (see Figure 1). Route multi-
conductor cable through a ¾" conduit to protect the cable 
from damage and to facilitate replacement if necessary.

Important: Locate Publication No. 199 “Steam Bath Important Safety Instructions”. This publication includes a Warning 
label that the contractor must install on the wall near the entrance to the steam room in a highly visible location. This 
label and its additional safety information are packaged with the generator in the envelope containing the installation 
instructions. If it is lost or missing contact Steamist (201-933-0700) for a replacement Publication No. 199. This publica-
tion along with all documents must be left with the owner. 

!

®