14
Trouble-shooting
Facts
Reason
Solution
Out
of
work
completely
1.Electrical fault;
2. Attaching plug gets loose;
3.Fuse burns out;
4.Power light doesn’t work
Check
and
maintain
by
professional staff
Big noise inside the
steam pipe with little
steam out
steam pipe gets bended under
horizontal level
Raise up steam pipe to let
condensate water backflow into
the machine
Spray head leakage
1.Spray head fracture
2. Operate flatwise
1.Replace spray head
2.Move the spray head up and
down vertically
Leakage in steam pipe
joint
1.Sealing ring aging
2. Linking joint looses
1. Replace sealing ring
2.Frap linking joint of steam pipe
Water in tank outflow
Tank fractures or has holes
Replace the tank
Hot water generates
inside the tank
Water pipe blocked
Eliminate the dirt or blockage
Steam is too small
1. voltage low
2. pipeline blocked by scale
1.Assemble voltage stabilizer
2.Eliminate the dirt or blockage
Tank deformation
1. Hot water added into the water
tank.
2. Other chemical added into the
water tank.
1. Use continually
2.Replace the tank
Power light works but
no steam comes out
1. Steam generator burns out
2.Inside components fail.
Check
and
maintain
by
professional staff