10 PROsine 2.5/3.0 Advanced Control System (ACS) Owner’s Manual
2.2.6. STATPOWER INFO
MENU OPTION
DISPLAY
DESCRIPTION
2.3.
Configuring “Installer-settable” Parameters
W
ARNING
The following information is for qualified installation/service personnel only.
Incorrect configuration can lead to battery damage and risk of fire hazard.
To navigate the menu and select parameters, follow these instructions:
1.
Press the
▲
or
▼
buttons to scroll up or down through the menu and values.
2.
Press the
ENTER
button to select the desired item.
3.
If the parameter is “installer settable”, it is meant to be configured by a
professional installer who is familiar with not only the system settings on the
inverter but also the ramification of changing those system settings. Setting
these parameters incorrectly could cause damage to connected equipment
(e.g. batteries) or could severely affect the performance of your system. You
will not be able to change parameters that are installer settable unless you
enter the ACS Panel into “installer” mode. To enter installer mode, hold
down
ESCAPE
and
▼
for approximately 5 seconds, until the audible signal is
heard from the ACS Panel. The parameter can now be adjusted. Exiting to
the top level menu, where voltage and current are displayed will disable
installer mode. Disable installer mode before putting the unit into service.
STATPOWER INFO:
TEL: 604-420-1585
STATPOWER INFO:
FAX: 604-420-1591
VERSION No. OF
THIS DISPLAY: 1
Main Switchboard number at Statpower
Technologies Corporation
Main fax number at Statpower
SELECT FROM:
AC INFORMATION
SELECT FROM:
BATTERY
SELECT FROM:
INVERTER
Software version used within ACS
(Advanced Control System) Display
SELECT FROM:
CHARGER
SELECT FROM:
SYSTEM INFO
VERSION No. OF
MASTER IC:
4
VERSION No. OF
ISOLATED IC: 4
SELECT FROM:
STATPOWER INFO
Software version of Master Processor
Software version of Isolated Processor