background image

C O M M E R C I A L

PATRIOT

LIGHT-DUTY

COMMERCIAL ELECTRIC WATER HEATERS

Designed for use as recovery heaters for
light-duty hot water supply service.
Patriot

PCE water heaters are available

with tank capacities from 6 through 119
gallons. They can be installed for non-
simultaneous and single element operation
(maximum input up to 6 KW), or for
simultaneous dual-element operation
(maximum input up to 12 KW).

Zinc-Plated Copper Sheath
Heating Elements Standard

• Medium watt density design disperses

element temperature over larger
surface contact area to minimize scale
buildup, maximize efficiency and pro-
long element life

• Element options from 1.5 KW to 6

KW (non-simultaneous or simultane-
ous operation), recoveries from 6 gph
to 49 gph at 100°F rise

Standard Voltages for
Easy Installation

• 120V, 277V single-phase, and 208V,

240V and 480V unbalanced 3-phase
delta

• Easily converted to single-phase at ter-

minal block (except for 208V with
6000 watt elements

• Single-element heater, single-phase only

(see chart for dual-element options)

Factory-Installed
Terminal Block

• Provides electrical service to heater and

connects to block

Factory-Wired Controls

• Temperature control (adjustable from

110°F to 170°F on single-element;
120°F to 180°F on dual-element models)

• Manual reset high temperature cutoff

per element (dual-element models)

• Factory wired for non-simultaneous

operation; easily converted to simulta-
neous operation

Glass-Lined Tank with
Anode Rod

• Provides long-lasting protection against

corrosion

Maximum Hydrostatic Working
Pressure: 150 psi

Meets or exceeds the thermal
efficiency and/or standby loss
requirements of the U.S.
Department of Energy and current
edition of ASHRAE/IESNA 90.1

Three-Year Limited Tank
Warranty

• Consult written warranty shipped with

water heater, or contact State for
complete information

Other Patriot™ PCE
Series Features

• Simplified, color-coded circuitry for

ease of service

• Bonderized undercoat on cabinet with

baked enamel finish

• Top inlet and outlet openings

• Foam insulation

• Drain valve

• UL-approved field conversion program

For more information on State

®

 contact:

State Water Heaters
500 Tennessee Waltz Parkway, Ashland City, TN 37015

800-365-0024 Toll-free USA

www.statewaterheaters.com

SCESS00106                                          August 2008R

Page 1 of 4              

                 ©2007 State Water Heaters Company

200694_SCESS00106.indd   1

200694_SCESS00106.indd   1

8/14/08   12:50:19 PM

8/14/08   12:50:19 PM

Содержание PATRIOT

Страница 1: ...lled Terminal Block Provides electrical service to heater and connects to block Factory Wired Controls Temperature control adjustable from 110 F to 170 F on single element 120 F to 180 F on dual element models Manual reset high temperature cutoff per element dual element models Factory wired for non simultaneous operation easily converted to simulta neous operation Glass Lined Tank with Anode Rod ...

Страница 2: ... YES YES YES YES NO NO NO NO NO NO 120V YES YES YES YES NO YES YES YES NO YES 208V YES YES YES YES YES YES YES YES YES YES 240V YES YES YES YES NO YES YES YES NO YES 277V NO NO YES YES NO YES YES YES NO YES 480V Terminal L2 Amperage Terminals L1 and L3 Amperage WATTAGE RECOVERY AND ELECTRICAL CHARACTERISTICS 15 20 25 30 41 46 51 61 40 F 61 81 91 101 122 100 F 6 8 10 12 16 18 20 24 24 32 36 41 49 1...

Страница 3: ... 4 NPT RELIEF VALVE OPENING ELECTRICAL CONNECTION INLET 3 4 FEMALE NPT INLET 3 4 FEMALE NPT TOP VIEW PCE 30 20LSA PCE 40 20LSA PCE 50 20LSA JUNCTION BOX 2 1 2 OUTLET 3 4 FEMALE NPT 3 4 NPT RELIEF VALVE OPENING BRASS DRAIN VALVE B C A 3 3 4 FRONT VIEW PCE 30 20LSA PCE 40 20LSA PCE 50 20LSA OUTLET 3 4 FEMALE NPT JUNCTION BOX TOP VIEW 3 4 NPT RELIEF VALVE OPENING 2 1 2 INLET 3 4 FEMALE NPT FRONT VIEW...

Страница 4: ...heating elements shall be medium watt density with zinc plated copper sheath or Incoloy sheath _______________ Each element shall be controlled by an individually mounted thermostat and high temperature cutoff switch The outer jacket shall be a baked enamel finish and provided with a full size control compartment for performance of service and maintenance through a hinged front panel and shall enc...