![Start italiana MAGLINK 16T Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/start-italiana/maglink-16t/maglink-16t_installation-manual_1364302006.webp)
Maglink 16T rev.08 2015-07 - ENG
6
COMPATIBLE PROBES MODEL LIST
The following probes models can be connected to MAGLINK16T console:
XMT EXD 485 polling mode
XMT SI 485 polling mode
XMT SI RF
XLR SI 485 polling mode
And auxiliary equipment:
Slave relay boards
Local or remote printer
Reed sensors
INSTALLATION
If mixed with air, the flammable vapors may cause explosion. Hazardous areas may be originated therefore by the presence of gas
or vapors.
Explosions or fires may cause damage, even lethal.
This console is not explosion proof.
Do not install the console in hazardous area.
INSTALLATION SITE
Regarding the installation site, it is necessary to consider that the console must be protected against vibrations and extreme climatic
conditions (in particular high/low temperatures, humidity, etc.) which may damage the electrical circuits. Please be sure to install in an
area protected from humidity and sprinkles of water.
220Vac ELECTRICAL CONNECTION
To realize the electrical connection please proceed as follow:
Switch off all the power switches on the electrical board panel.
Connect between board panel and the console using the appropriate connectors.
To connect driving force, please use cable with 3 wires whose section is at least 1,5 mm
2
(phase, neutral, earth) adequately
protected. Supply cable must be approved according to standards IEC 60227 or IEC 60245.
Be sure that the power plug used has ground round connection and that there is a protection device acting against short circuits
and overloads.
The power cable must be always easy recognizable and reachable since it has disconnecting function too.
Regarding probes connection, please refer to chapter “Probes connection”.
There is high voltage into the console which may be lethal.
The equipment installed in hazardous areas shall be explosion-proof or intrinsically safe according to the degree of protection
required.
INSTALLATION PROCEDURE
Fix the console to the wall using the supplied bracket along the product. To fix the console to the wall use bolt sleeves.
PRODUCT CLEANING
For product cleaning must be used a cloth dampened only with water and common detergents non aggressive without use of any
acids, chemical solvents or organic substances.
SAFETY INSTRUCTIONS
“Safety Instruction” attached.
Содержание MAGLINK 16T
Страница 1: ...INSTALLATION MANUAL CONSOLE MAGLINK 16T...
Страница 3: ...Maglink 16T rev 08 2015 07 ENG 3 30 07 15 8 GENERAL REVISION 11 X X...
Страница 29: ...Maglink 16T rev 08 2015 07 ENG 29...
Страница 43: ...Maglink 16T rev 08 2015 07 ENG 43 CERTIFICATION...
Страница 44: ...Maglink 16T rev 08 2015 07 ENG 44...
Страница 45: ...Maglink 16T rev 08 2015 07 ENG 45...
Страница 46: ...Maglink 16T rev 08 2015 07 ENG 46...
Страница 47: ...Maglink 16T rev 08 2015 07 ENG 47 NOTIFICATION...