9.
PROBLEMS/TROUBLESHOOTING GUIDE
Why is the sauna stove not heating up?
Check the following:
1.
Is the power on and the control switch in position I (
Chapter 2.5
)?
2.
Is the adjusted temperature higher than the temperature of the sauna?
3.
Has the temperature limiter gone off? (The cause must be determined before the next use)
4.
Are the fuses on the building’s switchboard intact?
5.
Is there an error code on the control panel display? If the device malfunctions, the display will show an error code. You can
attempt to solve the problem with the following error codes. If the problem is not solved with these instructions, contact technical
support or maintenance.
6.
Is the switchboard’s fuse intact? It is located in the upper right corner of the switchboard, when viewed from the bottom.
Error codes will not be displayed after the error situation has been resolved. E.g. when the sensor short circuit has been dealt with
or if the device has cooled sufficiently after overheating. After that, you can try to switch the device on again.
Error code / symptom:
Legend:
ER1 = There is no heat sensor or the temperature is too low.
Check the heat sensor's cabling and installation.
ER2 = Heat sensor has short-circuited or the temperature is too
high. Check the heat sensor's cabling and ensure that the sensor
is intact and that there are no short circuits. Also check the
Finlandia centre’s wiring on page 14.
The temperature in the device’s control electronics is too high.
See the previous part.
No error codes on the screen, but
the sauna is not heating up.
Check the overheating protection and ensure that it has not gone
off. The overheating protection may be turned off by carefully
pressing the button in the heat sensor box.
The stove light does not work
First confirm that the sauna stove's model features lights. If the
light is not turned on, contact technical support.
The sauna stove does not heat
properly
Remove the stones and check the condition of the resistors. If the
resistors are in working condition, contact technical support.